TL40 Fluke Electronics, TL40 Datasheet - Page 67

no-image

TL40

Manufacturer Part Number
TL40
Description
TEST LEAD SET RETRACTABLE TIPS
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL40

Current Rating
3A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs and Probes; Gray - Wire
Ratings
CAT III, 300V
Wire Insulation Material
Silicone
Includes
Needle Tip, Retractable 0-3" (0-76mm)
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Voltage - Max
-
Impedance
-
Cable Length
-
Other names
1590606

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL4003
Manufacturer:
ST
0
Part Number:
TL4003SG3
Manufacturer:
ST
0
Part Number:
TL4006
Manufacturer:
ST
0
Part Number:
TL40107B
Quantity:
5 510
Part Number:
TL40107B
Manufacturer:
PANASONIC
Quantity:
5 510
Part Number:
TL4011CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL4050A10IDBZR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL4050A10QDBZR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL4050A25IDBZR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL4050A25IDBZRG4
Manufacturer:
ICS
Quantity:
120
Part Number:
TL4050A25IDBZTG4
Manufacturer:
TI
Quantity:
343
Part Number:
TL4050A25QDBZR
Manufacturer:
TI
Quantity:
3 000
Part Number:
TL4050A25QDBZR
Manufacturer:
TI/德州仪器
Quantity:
20 000
* Requires PM9081/001 Adapter
** Requires PM9082/001 Adapter
For more information and detailed specifications, go to www.fluke.com/accessories
DC range
AC range
Accuracy
Bandwidth (-3 dB)
Zero error
adjustment
Maximum
conductor
diameter
Maximum
conductor size
Output levels
Output cable
Battery life
Warranty
Safety
AC/DC current clamp specifications
Power quality ac combo packs
for 4-phase current measurements
i430flex 4-pack
i5sPQ3
to 1 kHz: ± 3 % +
11.8 mm (0.46 in)
CAT II 600 V; CAT
0.1 A to 10 A; dc
100 A add 15 %;
20 kHz add 12 %
0.1 A to 100 A
1.6 meter with
10 mV/A, 100
0.1 A to 70 A
50 mA; up to
For use with DMMs, ScopeMeters
termination
80i-110s
One-year
40 hours
100 kHZ
III 300 V
1 AWG
up to
mV/A
BNC
Yes
Fluke current clamps
and Power Quality Analyzers
3.5 % + 0.5 A for
shrouded banana
30 mm (1.18 in)
750 MCM or 2-
1.2 meter with
(45 to 400 Hz)
CAT III 600 V
1 A to 400 A
1 to 400 A
500 MCM
60 hours
One-year
dc or ac
1 mV/A
3 kHz
i10
plugs
Yes
shrouded banana
30 mm (1.18 in)
2 % + 0.5 A for
750 MCM or 2-
1.2 meter with
(45 to 400 Hz)
CAT III 600 V
1 A to 600 A
1 to 1000 A
500 MCM
60 hours
One-year
dc or ac
1 mV/A
i1010
10 kHz
plugs
Yes
4 mA to 20 A rms
19 mm (0.75 in)
1.5 meter with
± 1 % ± 2 mA
shrouded dual
4 mA to 20 A
CAT III 300 V
dc to 20 kHz
banana plue
100 mV/A
250 MCM
30 hours
One-year
(-0.5 dB)
i0
Yes
4 mA to 20 A rms
2 meter with BNC
19 mm (0.75 in)
± 1 % ± 2 mA
dc to 100 kHz
4 mA to 20 A
CAT III 300 V
termination
100 mV/A
250 MCM
One-year
(-0.5 dB)
30 hours
i0s
Yes
80i-110s
AC/DC models
i0s and i0 Hall Effect
AC/DC Current Clamps
i30s
i30
i410
i1010
Use with multimeters or
recorders for non-intrusive
current measurements
Accessories
67