I2000 FLEX Fluke Electronics, I2000 FLEX Datasheet

no-image

I2000 FLEX

Manufacturer Part Number
I2000 FLEX
Description
CURRENT CLAMP AC 2000A FLEX
Manufacturer
Fluke Electronics
Type
AC Clampr
Datasheets

Specifications of I2000 FLEX

Style
Flexible Ring
Ac Current Range
20 ~ 2000A rms
Bandwidth
20kHz
Cable Length
78.740" (2000.00mm)
Max Conductor Size
7.000" (177.80mm)
Termination
Banana Plug, Double, Sheathed
Ratings
CAT III 600V
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
2584912
Fluke i2000 Flex
Electrical specifications
Current ranges: 20 A, 200 A, 2000 A ACRMS
Output sensitivity (ac-coupled): 100 mV, 10 mV,
1 mV per A
Load impedance: 100 kW minimum
Accuracy (at +25 °C): ± 1 % of range (45 Hz to
65 Hz)
Linearity (10 % to 100 % of range): ± 0.2 %
of reading
Noise: 8 mV ac rms (30 A), 2 mV ac rms (300 A,
3000 A)
Frequency range: 10 Hz to 20 kHz (-3 dB)
Phase error: < ± 1 º (45 Hz to 65 Hz), : ± 10 º
(at 20 kHz)
Position sensitivity (with cable > 25 mm from
the coupling): ± 2 % of range
External field (with cable > 200 mm from the
head): ± 1 % of range
AC Current Clamp
Power supply: 2 x AA/MN 1500/LR6 Alkaline,
200 hours, low battery indicator
Temperature coefficient: ± 0.08 % of reading
per °C
Working voltage (see Safety standards section):
600 V ac rms or dc
General specifications
Head cable length (double insulated): 610 mm
(24 in)
Head cable diameter: 14.3 mm (0.56 in)
Head bend radius: 38.1 mm (1.5 in)
Cable length (head to electronics): 2 m (6.56 ft)
Output connection: BNC with BNC to Banana
adapter included
Operating temperature range: 0 °C to +70 °C
(32 °F to 158 °F) (head and electronics)
The i2000 is an ac current probe Utilizing
the Rogowski principle. It can be used to
measure currents up to 2000 A when used
in conjunction with multimeters, recorders
or data loggers. The flexible and lightweight
measuring head allows quick and easy
installation in hard to reach areas.
Technical Data

I2000 FLEX Summary of contents

Page 1

... Fluke i2000 Flex AC Current Clamp Electrical specifications Current ranges 200 A, 2000 A ACRMS Output sensitivity (ac-coupled): 100 mV per A Load impedance: 100 kW minimum Accuracy (at +25 °C): ± range ( Hz) Linearity ( 100 % of range): ± 0 reading Noise rms (30 A rms (300 A, 3000 A) Frequency range kHz (-3 dB) Phase error: < ...

Page 2

... Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V acrms or dc and frequencies below 1 kHz. Ordering information i2000 Flex AC Current Clamp i2000 Flex connected to a Fluke 87V Digital Multimeter. EMC Standards EN 61326: 1998 +A1, A2, & A3 Fluke. Keeping your world Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B ...