H5CX-L8D AC24/DC12-24Q Omron, H5CX-L8D AC24/DC12-24Q Datasheet - Page 33

RELAY TIMER DGTL SPDT 12-24VDC

H5CX-L8D AC24/DC12-24Q

Manufacturer Part Number
H5CX-L8D AC24/DC12-24Q
Description
RELAY TIMER DGTL SPDT 12-24VDC
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-L8D AC24/DC12-24Q

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12 ~ 24VDC, 24VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CX-L8D-AC24DC1224
H5CXL8DAC24DC1224
H5CXL8DAC24DC1224Q
Z2370
■ List of Settings
Fill in your set values in the set value column of the following tables and utilize the tables for quick reference.
Timer/Twin Timer Selection Mode
Settings for Timer Operation
Run Mode when Output Mode Is Not Z
Run Mode when Output Mode = Z
Function Setting Mode
Timer/Twin Tim-
er selection
DIP switch moni-
tor
Present value,
set value
Present value,
ON duty ratio
Present value,
cycle time
Time range
Timer mode
Output mode
Output time
Input signal width
NPN/PNP input mode
Display color
Key protect level
Parameter
name
Parameter name
Parameter name
Parameter name
Cycle time
ON duty ratio
Present value
Present value
Set value
Present value
func
dip
Parameter
---
---
---
---
---
---
---
---
---
---
---
---
---
Parameter
---
---
---
---
---
---
---
---
---
---
---
tim/twin
on/off
Parameter
timr
timm
outm
otim
iflt
imod
colr
kypt
Parameter
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
0 to 100
Same as cycle time above
Same as cycle time above
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
Same as set value
Setting range
--.--s/---.-s/----s/--min--s/---.-min/----min/--
h--min/---.-h/----h/-.---s
up/down
a/a-1/a-2/a-3/b/b-1/d/e/f/=
hold/0.01 to 99.99
20ms/1ms
npn/pnp
red/org/r-o/o-r
kp-1/kp-2/kp-3/kp-4/kp-5
Setting range
Setting range
Setting range
tim
off
Default value
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
Same as left
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
0
Same as left
Same as left
Default value
Default value
--.--s
up
a
hold
20ms
npn
red
kp-1
Default
value
---
---
s
s
s
min; s
min
min
h; min
h
h
s
Same as left
s
s
s
min; s
min
min
h; min
h
h
s
%
Same as left
Same as left
Unit
---
---
---
s
---
---
---
---
Unit
Unit
Unit
H5CX-A/-L
Set value
Set value
Set value
Set value
33