H5CX-A11 AC100-240 Omron, H5CX-A11 AC100-240 Datasheet - Page 22

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-A11 AC100-240

Manufacturer Part Number
H5CX-A11 AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheet

Specifications of H5CX-A11 AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
11 Pin Socketable
Timing Adjustment Method
DIP Switches
Timing Initiate Method
Input Voltage, Trigger Signal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H5CX-A11-AC100-240
H5CXA11AC100240
Z2369
Timing Charts
Timer Operation
The gate input is not included in the H5CX-L8@ models.
Timing
diagram
Timing
diagram
Timing
diagram
Timing
diagram
t
Control output
Control output
One-shot output
Control output
Control output
Start signal
Start signal
Start signal
Start signal
Set value
Set value
Set value
Set value
Set value
Set value
Set value
Set value
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
Power
Power
Power
Reset
Reset
Power
Reset
Gate
Reset
Sustained output
Gate
Gate
Gate
0
0
0
0
0
0
0
0
t
Output mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.)
t
t
t
Output mode A-1: Signal ON delay 2 (Timer resets when power comes ON.)
Output mode A-2: Power ON delay 1 (Timer resets when power comes ON.)
Output mode A: Signal ON delay 1 (Timer resets when power comes ON.)
Either one-shot output or sustained output can be selected.
t
t
t
*
**
*
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e., same
function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
*
*
Timing starts when the reset input goes OFF.
The start signal disables the timing function (i.e.,
same function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing starts when the start signal goes ON, and is
reset when the start signal goes OFF.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Start signal
input
Output is instantaneous when setting is 0.
Output is instantaneous when setting is 0.
Output is instantaneous when setting is 0.
Basic Operation
Output
Timing starts when the start signal goes ON.
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
The control output is controlled using a sustained or
one-shot time period.
Start signal
input
Output is instantaneous when setting is 0.
Start signal input is disabled during timing.
Power
Output
Basic Operation
Power
Basic Operation
Basic Operation
Output
Power
Output
Power
**
Timing
Timing
Timing
Timing
Sustained
H5CX-A/-L
22