H3AM-NSR-A AC100-240 Omron, H3AM-NSR-A AC100-240 Datasheet - Page 3

TIMER SOLID STATE W/ RESET

H3AM-NSR-A AC100-240

Manufacturer Part Number
H3AM-NSR-A AC100-240
Description
TIMER SOLID STATE W/ RESET
Manufacturer
Omron
Series
H3AMr
Type
Mechatronic Timerr
Datasheets

Specifications of H3AM-NSR-A AC100-240

Analog / Digital
Analog
Control Method
Dial
Display Type
Dial
Voltage Rating
100 VAC to 240 VAC
Mounting
Panel
Features
Large setting dial and moving pointers
Input Type
Voltage
Output Type
Relay - DPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3AM-NSR-AAC100-240
H3AMNSRAAC100240
J CHARACTERISTICS
Note: A separately sold waterproof gasket (Y92S-35) is necessary to ensure IP65 waterproofing between the Timer and installation panel.
H3AM
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Enclosure rating
Weight
The H3AM-NSj-j-300 model with waterproof gasket is available.
±0.7% FS max.
±2% FS max.
Power reset: 0.5 s max.
Reset input time: 0.5 s max.
±1% FS max.
±2% FS max.
100 MΩ max. (at 500 VDC)
2,000 VAC (50/60 Hz) for 1 min between exposed non-current-carrying metal parts and
current-carrying metal parts
2,000 VAC (50/60 Hz) for 1 min between the operating circuit and control output terminals
1,000 VAC (50/60 Hz) for 1 min between the operating power supply circuit and control input circuit)
1,000 VAC (50/60 Hz) for 1 min between contacts not located next to each other
2,000 VAC (50/60 Hz) for 1 min between contacts of opposite poles
3 kV between power terminals
4.5 kV between exposed non-current-carrying metal parts and current-carrying metal parts
±1.5 kV (between power terminals) square-wave noise by a noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz, 0.75-mm single amplitude
Malfunction: 10 to 55 Hz, 0.5-mm single amplitude
Destruction: 300 m/s
Malfunction: 150 m/s
Mechanical: 5,000,000 times min. (under no load at 1,800 times/h)
Electrical: 100,000 times min. (5-A at 250 VAC, resistive load at 1,800 times/h)
(EMI): 50081-2
Emission Enclosure: EN55022 class A
Emission AC Mains:EN55022 class A
(EMS): 50082-2
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)
Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3);
Immunity Power Frequency Magnetic Fields: EN61000-4-8: 30 A/m (50 Hz) (level 4)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to line; 2 kV line to ground (level 3)
IP65 (front panel only) (see note) IP20 (terminal section)
Approx. 350 g
2
2
(approx. 30G)
(approx. 15G) (100 m/s
ENV50204: 10 V/m (900 MHz±5 MHz) (level 3)
2
(approx. 10G) in the front/back direction)
H3AM
3

Related parts for H3AM-NSR-A AC100-240