H3DE-H AC/DC48 S Omron, H3DE-H AC/DC48 S Datasheet - Page 33

no-image

H3DE-H AC/DC48 S

Manufacturer Part Number
H3DE-H AC/DC48 S
Description
TIMER 22.5MM .1-12S DIN MNT
Manufacturer
Omron
Series
H3DE-Hr
Datasheet

Specifications of H3DE-H AC/DC48 S

Relay Type
Integrated
Function
Off-Delay
Circuit
SPDT (1 Form C)
Delay Time
0.1 Sec ~ 12 Sec
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
48VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Timing Adjustment Method
Screwdriver Slot
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3DE-HAC/DC48S
H3DEHACDC48S
■ Operation (H3DE-H)
An interval of 3 s minimum is required to turn on the H3DE after the
H3DE is turned off. If the H3DE is turned on and off repeatedly with
an interval of shorter than 3 s, the internal parts of the H3DE may
deteriorate and the H3DE may malfunction.
If it is required that the output be turned on repeatedly with an inter-
val of shorter than 3 s, consider use of the H3DE-M2/-M1 in mode D
(signal OFF-delay).
■ Precautions for EN61812-1
The H3DE as a built-in timer conforms to EN61812-1 provided that
the following conditions are satisfied:
The output section of the H3DE is provided only with basic isolation.
To ensure reinforced isolation required by the EN61812-1, provide
supplementary basic isolation on the load side connected to the out-
put.
The H3DE itself is designed according to the following:
• Overvoltage category III
• Pollution degree 2
On the above basis:
Operation parts on the front and bottom: Reinforced isolation
- With clearance of 5.5 mm and creepage distance of 5.5 mm at
Output: Basic isolation
- With clearance of 3 mm and creepage distance of 3 mm at
230 VAC
230 VAC
Conformance
Power
Output
state 1
Output
state 2
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
3 s min.
In the interest of product improvement, specifications are subject to change without notice.
■ Environment
When using the Timer in an area with excess electronic noise, sepa-
rate the Timer, wiring, and the equipment which generates the input
signals as far as possible from the noise sources. It is also recom-
mended to shield the input signal wiring to prevent electronic interfer-
ence.
Organic solvents (such as paint thinner), as well as very acidic or
basic solutions can damage the outer casing of the Timer.
Do not use the Timer in places where it is exposed to dust, corrosive
gas, or direct sunlight.
When storing the Timer, make sure that the ambient temperature
and humidity are within the rated values. Leave the Timer at room
temperature for at least three hours before using the Timer if it has
been stored at an ambient temperature of –10°C or below.
■ Others
If the Timer is mounted on a control board, dismount the Timer from
the control board or short-circuit the circuitry of the power board
before carrying out a voltage withstand test between the electric cir-
cuitry and non current-carrying metal part of the Timer, in order to
prevent the internal circuitry of the Timer from damage.
It must be noted that although the electrical life expectancy of the
H3DE Timer shown in the catalog is the same as the H3DR Timer
shown in the catalog, the actual performance varies because the
built-in relays are different as follows:
Built-in relay for the H3DR: G2R; 100,000 operations min.
Built-in relay for the H3DE: G6RN; 50,000 operations min.
(10 A for SPDT and 5 A for DPDT at
250 VAC, resistive load at
1,800 operations/h.)
(8 A at 250 VAC, resistive load at
360 operations/h.)
H3DE
33

Related parts for H3DE-H AC/DC48 S