H5CX-L8-N AC100-240 Omron, H5CX-L8-N AC100-240 Datasheet - Page 30

RELAY TIMER DGTL SPDT 100/240VAC

H5CX-L8-N AC100-240

Manufacturer Part Number
H5CX-L8-N AC100-240
Description
RELAY TIMER DGTL SPDT 100/240VAC
Manufacturer
Omron
Series
H5CXr
Datasheets

Specifications of H5CX-L8-N AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage, Trigger Signal
Time Range
0.001s-9999hr
Power Consumption
6.2VA
Reset Time
20ms
Character Size
11.5mm
Time Range Min
0.001s
Supply Voltage Min
100VAC
Connector Type
8-Pin Socket
Signal Input Type
PNP/NPN
No. Of Digits / Alpha
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
PNP/NPN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H5CXL8NAC100240
Z2999
30
H5CX-A@-N/-L@-N
Twin Timer
Models with Instantaneous Contact Outputs
Note: H5CX-L8E@-N Precautions
Instantaneous
Instantaneous
Mode ton-1: Flicker ON start 2 (Timer does not reset when power comes ON.)
Basic operation
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Mode ton: Flicker ON start 1 (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Start signal
Time-limit
Time-limit
Power
Power
output
output
output
output
Set the Timer’s set value before using the Timer in a self-holding circuit.
Output
Power
the set time is too short.
Set the value to at least 100 ms (contact output
type).
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
input
*
Ton time
Toff time
Timing
ON
Toff time
Ton time
Timing
OFF
Toff time
Ton time
Timing
ON
(a + b = OFF time)
Toff time
a
Ton time
b
Detailed operation
Detailed operation
Detailed operation
Instantaneous
Instantaneous
Instantaneous
Instantaneous
contacts, NO
contacts, NO
contacts, NO
contacts, NO
contacts, NC
contacts, NC
contacts, NC
contacts, NC
Control output
Reset Key
Reset Key
Time-limit
Time-limit
Time-limit
Time-limit
UP
DOWN
Start signal
Power
Power
OFF time
OFF time
ON time
ON time
Power
Reset
Gate
0
0
t-a
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
t-b
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
t-off
t-on
t-on
t-off
t-off
t-on
t-b
t-a
Rt
Rt
t-off
t-on
t-on
t-off
t-off
t-on
t-b
t-a
t-b
t-a
Rt
Rt
t-a
t-b

Related parts for H5CX-L8-N AC100-240