H3CR-F8 DC12 Omron, H3CR-F8 DC12 Datasheet - Page 9

RELAY REPEAT CYCLE ANALOG 30HRS

H3CR-F8 DC12

Manufacturer Part Number
H3CR-F8 DC12
Description
RELAY REPEAT CYCLE ANALOG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Type
Solid State Twin Timerr
Datasheet

Specifications of H3CR-F8 DC12

Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
12VDC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Analog / Digital
Analog
Control Method
Dial
Voltage Rating
12 VDC
Mounting
DIN Rail
Display Type
Dial
Size
52.3 mm x 48 mm x 48 mm
Features
Easy sequence checks through instantaneous outputs for a zero set value at any time range
Input Type
Voltage
Rohs Compliant
YES
Contact Configuration
DPDT
Timing Adjustment
Knob
Relay Mounting
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F8-DC12
H3CR-F8-DC12
H3CRF8DC12
Q3594182
Z2815
■ Ratings
Note: 1. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
■ Characteristics
Note: Refer to the Life-test Curve.
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)
Operating voltage range
Power reset
Power consumption
Control outputs
Accuracy of operating
time
Setting error
Accuracy of Star-delta
transfer time
Reset voltage
Influence of voltage
Influence of temperature ±1% FS max.
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Degree of protection
Weight
2. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
http://www.ia.omron.com/
±0.2% FS max.
±5% FS ±50 ms max.
±25% FS + 5 ms max.
10% max. of rated voltage
±0.2% FS max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 294 m/s
Operating:
Storage:
Operating:
Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g
−10°C to 55°C (with no icing)
−25°C to 65°C (with no icing)
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)
35% to 85%
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
100 to 120 VAC: approx. 6 VA (2.6 W) at 120 VAC
200 to 240 VAC: approx. 12 VA (3.0 W) at 240 VAC
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
2
2
three times each in six directions
three times each in six directions
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)
H3CR-G