H3CR-F8N AC100-240 Omron, H3CR-F8N AC100-240 Datasheet - Page 3

RELAY REPEAT CYCLE ANALOG 30HRS

H3CR-F8N AC100-240

Manufacturer Part Number
H3CR-F8N AC100-240
Description
RELAY REPEAT CYCLE ANALOG 30HRS
Manufacturer
Omron
Series
H3CR-Fr
Datasheets

Specifications of H3CR-F8N AC100-240

Output Type
Mechanical Relay
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Timing Range
0.05 s to 30 Hrs
Supply Voltage
100 V to 240 V
Accuracy
+/- 0.2 %
Current Rating (max)
5 A
Display Type
Hand Dial
Operating Temperature Range
- 10 C to + 55 C
Contact Configuration
DPDT
Nom Input Voltage
240VAC
Delay Time Range
0.05s To 30h
Timing Adjustment
Knob
Relay Mounting
DIN Rail
Supply Voltage Ac, Min
100VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H3CR-F8N-AC100240
H3CRF8NAC100240
Z2385
Specifications
■ General
■ Time Ranges
0.05 s to 30 h Models
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
1.2 s to 300 h Models
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
■ Ratings
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
Operating mode
Pin type
Operating/Reset method
Output type
Mounting method
Approved standards
Setting
Setting
Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC
Operating voltage range
Power reset
Power consumption
Control outputs
2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
Time unit
Time unit
Item
1.2
3
12
30
1.2
3
12
30
0.05 to 1.2
0.3 to 3
1.2 to 12
3 to 30
1.2 to 12
3 to 30
12 to 120
30 to 300
Flicker OFF start
11-pin
Time-limit operation/Time-limit reset or self-reset
Relay output (DPDT)
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.
×10 s (10 sec)
s (sec)
H3CR-F
85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models
Minimum power-opening time: 0.1 s
100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC
24 VAC/VDC:
48 to 125 VDC: approx. 1.5 W at 125 VDC
12 VDC:
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
1.2 to 12
3 to 30
12 to 120
30 to 300
1.2 to 12
3 to 30
12 to 120
30 to 300
8-pin
×10 min (10 min)
×10 s (10 sec)
approx. 2 VA (1.7 W) at 24 VAC
approx. 1 W at 24 VDC
approx. 1 W at 12 VDC
H3CR-F8
0.12 to 1.2
0.3 to 3
1.2 to 12
3 to 30
0.12 to 1.2
0.3 to 3
1.2 to 12
3 to 30
Flicker ON start
11-pin
min (min)
h (hrs)
H3CR-FN
1.2 to 12
3 to 30
12 to 120
30 to 300
8-pin
×10 h (10 hrs)
H3CR-F8N
h (hrs)
H3CR-F
3