H3CR-A8 AC24-48/DC12-48 Omron, H3CR-A8 AC24-48/DC12-48 Datasheet - Page 18

RELAY ANALOG SET DPDT 8PIN

H3CR-A8 AC24-48/DC12-48

Manufacturer Part Number
H3CR-A8 AC24-48/DC12-48
Description
RELAY ANALOG SET DPDT 8PIN
Manufacturer
Omron
Series
H3CR-Ar

Specifications of H3CR-A8 AC24-48/DC12-48

Mounting Type
Socket
Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 300 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 240VAC
Voltage - Supply
24 ~ 48VAC, 12 ~ 48VDC
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Time Range
0.05 Sec. To 300 Hr.
Supply Voltage Ac, Min
24VAC
No. Of Timing Functions
4
Body Material
94B1639
No. Of Pins
8
Supply Voltage Ac, Max
48VAC
Load Current Rms Max
5A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-A8-AC24-48/DC12-48
H3CRA8AC2448DC1248
Z2380
2. Signal Start/Instantaneous Operation/
E Mode: Interval
1. Power-ON Start/Instantaneous Operation/
This function is useful for the operation of a machine for a specified
period after power is ON.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Time-limit Reset
Time-limit Reset
Power (2 and 10)
Power (2 and 10)
Power indicator
Start (2 and 6)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
NC (1 and 4)
NO (1 and 3)
Externally short-circuited
Start signal (NO to NC to NO)
(Power continuously supplied)
Lit
Power
supply
Power
supply
Flashing
Lit
2. Signal Start/Instantaneous Operation/
This function is useful for the repetitive control such as the filling of
liquid for a specified period after each Signal start input.
Control output: NC (8 and 11)
Control output: NO (9 and 11)
Time-limit Reset
Power (2 and 10)
Start (2 and 6)
NC (1 and 4)
NO (1 and 3)
Start signal
(Power continuously supplied)
t
Power
supply
t
H3CR-A
18