PVA1354 International Rectifier, PVA1354 Datasheet - Page 2

IC RELAY 100VAC/DC 300MA 8-DIP

PVA1354

Manufacturer Part Number
PVA1354
Description
IC RELAY 100VAC/DC 300MA 8-DIP
Manufacturer
International Rectifier
Series
PVA, BOSFET®r
Datasheet

Specifications of PVA1354

Circuit
SPST-NO (1 Form A)
Output Type
AC, DC
On-state Resistance
5 Ohm
Load Current
300mA
Voltage - Input
1.2VDC
Voltage - Load
0 ~ 100 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
8-DIP (0.300", 7.62mm), 4 Leads
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PVA1354
Manufacturer:
IR
Quantity:
5 510
Part Number:
PVA1354
Manufacturer:
IR
Quantity:
20 000
Part Number:
PVA1354N
Manufacturer:
IOR
Quantity:
20 000
Part Number:
PVA1354NPBF
Manufacturer:
TOKO
Quantity:
4 000
Part Number:
PVA1354NPBF
Manufacturer:
IR
Quantity:
15
Part Number:
PVA1354NS
Manufacturer:
IR
Quantity:
20 000
Part Number:
PVA1354S
Manufacturer:
IR
Quantity:
20 000
Electrical Specifications (-40 C
INPUT CHARACTERISTICS
Minimum Control Current (see figures 1 and 2)
Maximum Control Current for Off-State Resistance at 25°C
Control Current Range (Caution: current limit input LED. See figure 6)
Maximum Reverse Voltage
OUTPUT CHARACTERISTICS
Operating Voltage Range
Maxiumum Load Current 40°C (see figures 1and 2)
Response Time @25°C (see figures 7 and 8)
Maximum On-state Resistance 25°C
Minimum Off-state Resistance 25°C @ 80 VDC (see figure 5)
Maximum Thermal Offset Voltage @ 5.0mA Control
Minimum Off-State dv/dt
Output Capacitance (see figure 9)
GENERAL CHARACTERISTICS (PVA1352 and PVA1354)
Dielectric Strength: Input-Output
Insulation Resistance: Input-Output @ 90V
Maximum Capacitance: Input-Output
Max. Pin Soldering Temperature (1.6mm below seating plane, 10 seconds max.)
Ambient Temperature Range:
Maximum T (on) @ 12mA Control, 50 mA Load, 50 VDC
Maximum T (off) @ 12mA Control, 50 mA Load, 50 VDC
For 200mA Continuous Load Current
For 250mA Continuous Load Current
For 125mA Continuous Load Current
(Pulsed) (figure 4) 50 mA Load, 5mA Control
Replaced by PVA13N
DC
T
A
+85 C unless otherwise specified
Operating
Storage
PVA1352
PVA1352
10
10
12
@ 25°C - 50% RH
8
-40 to +100
0 to ± 100
-40 to +85
2.0 to 25
2500
+260
1000
315
300
2.0
5.0
5.0
7.0
0.2
1.0
10
50
15
5
PVA1354
PVA1354
10
10
pF @ 50VDC
mA@25°C
mA@40°C
mA@85°C
mA(DC)
µA(DC)
mA
V(DC)
V
µvolts
V
Units
Units
Units
V/µs
DC
(peak)
pF
µs
µs
RMS
C
(DC)

Related parts for PVA1354