84138001 Crouzet C/O BEI Systems and Sensor Company, 84138001 Datasheet

SSR RHP 20A/240VAC AC INPUT

84138001

Manufacturer Part Number
84138001
Description
SSR RHP 20A/240VAC AC INPUT
Manufacturer
Crouzet C/O BEI Systems and Sensor Company
Series
RHPr
Datasheet

Specifications of 84138001

Circuit
SPST-NO (1 Form A)
Output Type
AC, Zero Cross
Load Current
20A
Voltage - Input
90 ~ 260VAC
Voltage - Load
90 ~ 260 V
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Hybrid Power Relay – RHP (Single Pole Relay)
Operation:
Contactor
Output of the contactor is closed when the input is On.
Output of the contactor is opened when the input is Off.
Led is On when the output is closed.
Bistable Relay
Output of the bistable changes of status for every pulse on the input
and stays in its position between pulses.
Front plate push button allows to select the operation mode:
Stop – led off – output off
On forced – led flashing – output on
Auto – led on – bistable relay operation
Day/night contactor
Output of the contactor is closed when the input is On
Output of the contactor is opened when the input is Off.
Front plate push button allows to select the operation mode:
Stop – led off – output off
On forced – led flashing – output on – back to the Auto mode at the
next change of the input.
Auto – led on – day/night contactor operation
Compliance
CEI/EN 60947-4-3 (industrial environment)
CEI/EN 60669-2-1 (household environment)
CEI/EN 60601-1 (medical environment)
CEI/EN 60947-7-1 (connections in industrial env.)
CEI/EN 60998-2-1 (connections in household env.
Insulation:
dielectric CEI/EN 60669-2-1:
Insulation CEI/EN 60669-2-1:
Vibrations CEI/EN 60068-2-6:
20 Amp output (Resistive only)
Every SSR advantage without the drawbacks
Lifetime > 5 million operations full load
Noiseless
Functions: contactor – bistable
17.5 mm DIN rail mount
UL/c UL (listed)
Label NF-USE
CE compliant
Installation category: 3
pollution: 3
CEI60664-1: 4KV/3
2 KV/1mm / 1mA / 50 Hz
> 5MΩ/500VDC / 1 min
60
44
frequencies: 10 to 55 Hz
magnitude: 0,35 mm
5.5
Products and specifications subject to change without notice.
Tel: (877) 502-5500 / FAX: (619) 710-8540 / www.crouzet-usa.com
17.5
Consult factory for application assistance.
1
2
N
1
2
LOAD
3
4
3
I
4 A2
90...
260V~
A1
A2
A1
Type
Part number
AC input contactor
DC input contactor
AC input distable relay
AC input day/night contactor
Specifications
Power supply
Frequency
Max. power consumption
Input Control
Voltage
Frequency
Value
Min. time input
Output
Voltage
Max. current
Overload current 20A
Min current
Frequency
Contact
Switching frequency
lifetime
leakage current
Acoustic noise
terminal capacity
2 x 2.5 mm2 without ferrule
1 x 4 mm2 without ferrule
Torque
Operating temperature:
Storage temperature
Humidity
Housing
protection
(CEI 60529)
weight
Input OFF
Input ON
ON position
switching
90-260 Vac
50 / 60 Hz
11 VA
90-260 Vac
50 / 60 Hz
0 – 46 Vac
76 – 260 Vac
50 ms
90-260 Vac
20A in AC1 / AC51 / AC7a
AC-51: 1,25 x Ie – 60s: 50 – 30
(CEI 60947-4-3)
100mA in AC1 / AC51 / AC7a
50 / 60 Hz
N.O.
> 5,000,000
< 5 mA
< 35 dB @ 1m
< 50 dB @ 0.5m
2 x 1.5 mm2 with ferrule
1Nm maxi. screw M3 (CEI 60947-1)
–5°C to +55°C
–40°C to +85°C
90 to 95% non-condensing
self extinguish
housing IP 50
terminal IP 20
70 gr
20 / min
0-32 Vdc
0 – 1 Vdc
4 – 32 Vdc
50 ms
84 138 001
84 138 000
84 138 101
84 138 201
1-3
1

Related parts for 84138001

Related keywords