DRA-CN024D05 Crydom Co., DRA-CN024D05 Datasheet

RELAY SSR 3.5A 24VDC DIN-RAIL

DRA-CN024D05

Manufacturer Part Number
DRA-CN024D05
Description
RELAY SSR 3.5A 24VDC DIN-RAIL
Manufacturer
Crydom Co.
Series
DRACNr
Datasheets

Specifications of DRA-CN024D05

Package / Case
Module
Termination Style
Screw Terminal
Circuit
SPST-NO (1 Form A)
Output Type
DC
Load Current
3.5A
Voltage - Input
3 ~ 12VDC
Voltage - Load
0 ~ 24 V
Mounting Type
DIN Rail
Control Voltage Range
3 VDC to 12 VDC
Load Voltage Rating
24 V
Off State Leakage Current (max)
0.001 mA
Load Current Rating
3.5 A
Contact Form
DPST
Output Device
AC Output
Mounting Style
DIN Rail
Control Voltage Type
DC
Operating Voltage Range
0VDC To 24VDC
Peak Surge Current
9A
Switching Mode
Zero Cross
Control Voltage Max
12V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CC1746

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DRA-CN024D05
Manufacturer:
Crydom
Quantity:
135
DRACN Series
PRODUCT SELECTION
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
3-12 VDC
15-30 VDC
90-140 VAC
190-250 VAC
Description
Operating Voltage
Maximum Load Current @ 40°C (2)
Minimum Load Current [mA]
Maximum Blocking Voltage
Maximum Surge Current [Apk]
Maximum I²t for fusing 50/60Hz (1/2 cycle) [A² sec]
Typical On-State Voltage Drop @ Rated Current (V)
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum PWM (Hz) (3)
Switch Configuration
• 6.2mm Din-Rail Mount (35 mm) SSR Assembly
• Ratings 24VDC @ 3.5A, 48VDC @ 100mA and 240VAC @ 2A
• 5 & 24 VDC and 120V & 240 VAC Control
• UL & cUL recognized @ 40°C, 100K-Cycle Endurance Test (SSR Only)
• CE & RoHS Compliant
• Yellow LED input status indicator
DRA-CN024D120
DRA-CN024D240
DRA-CN024D05
DRA-CN024D24
3.5 A
DRA-CN024DXX
9 A (10 ms)
0-24 VDC
30 VDC
0.001
3.5 A
N.O.
N.A.
500
0.4
1
DRA-CN048D120
DRA-CN048D240
DRA-CN048D05
DRA-CN048D24
100 mA
DRA-CN048DXX
300 mA (10 ms)
0-48 VDC
100 mA
60 VDC
DRA-CN240A120
DRA-CN240A240
0.001
DRA-CN240A05
DRA-CN240A24
N.O.
N.A.
500
1.0
1
2 A
120/115 A (16.6/20 ms)
DRA-CN240AXX
24-280 VAC
600 VAC
285/260
N.O.
N.A.
2 A
70
1.1
4.0

Related parts for DRA-CN024D05

DRA-CN024D05 Summary of contents

Page 1

... Maximum Surge Current [Apk] Maximum I²t for fusing 50/60Hz (1/2 cycle) [A² sec] Typical On-State Voltage Drop @ Rated Current (V) Maximum Off-State Leakage Current @ Rated Voltage [mA] Maximum PWM (Hz) (3) Switch Configuration 3.5 A 100 mA DRA-CN024D05 DRA-CN048D05 DRA-CN024D24 DRA-CN048D24 DRA-CN024D120 DRA-CN048D120 DRA-CN024D240 DRA-CN048D240 DRA-CN024DXX 0-24 VDC 3 ...

Page 2

... All parameters at 25°C unless otherwise specified. (2) See derate curves for more information (3) Operating frequency above 500Hz will damage the SSR (DC output only). (4) Turn-on time for random turn-on version is 0.1msec (5) 3.75KV for CN048Dxx DRA-CN024D05 DRA-CN024D24 3-12 VDC 15-30 VDC 3.0 VDC 15 VDC 1 ...

Page 3

MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION ...

Page 4

AGENCY APPROVALS ACCESSORIES Rev. 022310 ...

Page 5

...

Page 6

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords