AHKA21 Panasonic Electric Works, AHKA21 Datasheet
AHKA21
Specifications of AHKA21
Available stocks
Related parts for AHKA21
AHKA21 Summary of contents
Page 1
... Compact with high-capacity Enables high-capacity control for 1 Form for 2 Form C 3. Types for wide range of applications Range includes relays with operation indicators, built-in diodes to absorb relay coil surge, and built-in CR circuits. 4. Cadmium-free contacts 5. UL/C-UL and TÜV approved parts available. Compliance with Japanese Electrical Appliance and Material Control Law is standard ...
Page 2
... AHK115X0 AHK115X1 AHK115Y0 AHK115Y2 Item Item 2 Form C Part No. AHK22106 AHK22112 AHK22124 AHK22148 AHK221X0 AHK21112 AHK21124 AHK21148 AHK211X0 AHK211X1 AHK211Y0 AHK211Y2 2 Form C Part No. AHK22306 AHK22312 AHK22324 AHK22348 AHK223X0 2 Form C Part No. AHK215X0 AHK215X1 AHK215Y0 AHK215Y2 Part No. AHKA21 AHKA21P Part No. HL1-SS-K HL2-SS-K HL1-PS-K HL2-PS-K ...
Page 3
RATING 1. Coil data 1) AC coils Nominal coil current, mA Coil voltage 50Hz 60Hz 12V AC 111 100 24V 48V 100/110V AC 13.4/14.7 12/13.2 110/120V AC 12.2/13.5 10.9/11.9 200/220V AC 6.7/7.4 6/6.6 Notes: ...
Page 4
HK (AHK) REFERENCE DATA 1-(1). Max. switching capacity (1 Form C type resistive load 100 250 500 Contact voltage, V 2-(2). Coil temperature rise (1 Form C/DC type) Measured portion: Inside the coil Ambient temperature: ...
Page 5
DIMENSIONS (Unit: mm inch) 1. Plug-in type (1 Form C) including diode/CR 20.8 .819 10 .394 3 7 14.2 .559 2. Plug-in type (2 Form C) including diode/CR 20.8 .819 10 .394 14.2 .559 All Rights ...
Page 6
... HK screw terminal socket (Finger protect type) External dimensions .276 2-4.5×6 2-.177×6 mounting holes Max. 28.5 General tolerance: ±0.5 ±.020 Max. 1.122 4. Plug-in type sockets HL1 socket External dimensions HL1 Socket (HL1-SS-K) HL2 Socket (HL2-SS-K) Mounting hole diagram 7 Max. 30 M3.5 .138 Max. 1.181 terminal screw 3 ...
Page 7
... PC board type sockets HL1 PC board type socket (HL1-PS-K) HL2 PC board type socket (HL2-PS-K) PC board pattern (Bottom view) 1 Form C 2 Form C 2.4 dia. hole 10 .394 .094 dia. 4.7 .185 17.45 17.45 .687 12.75 .687 .502 6.75 6.75 15.3 10 .266 .266 .602 ...
Page 8
HK (AHK) NOTES 1. Coil operating power 1) DC coil To ensure proper operation, the voltage applied to both terminals of the coil should be ±5% (at 20°C 68°F) the rated operating voltage of the coil. Also, be aware that ...