HJ4-SFD-S Panasonic Electric Works, HJ4-SFD-S Datasheet - Page 4

SOCKET TERM 2/4CH FOR HJ4 RELAYS

HJ4-SFD-S

Manufacturer Part Number
HJ4-SFD-S
Description
SOCKET TERM 2/4CH FOR HJ4 RELAYS
Manufacturer
Panasonic Electric Works
Series
HJr
Type
Socketr
Datasheet

Specifications of HJ4-SFD-S

Number Of Positions
14
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Features
Mounting Hardware
For Use With/related Products
HJ4 Relays
For Use With
HJ4-T-DC48V - RELAY PWR 5A 48VDC TEST PLUG-INHJ4-T-DC110V - RELAY PWR 5A 110VDC TEST PLUG-INHJ4-T-AC48V - RELAY PWR 5A 48VAC TEST PLUG-INHJ4-T-AC24V - RELAY PWR 5A 24VAC TEST PLUG-INHJ4-T-AC200V - RELAY PWR 5A 200VAC TEST PLUG-INHJ4-T-AC12V - RELAY PWR 5A 12VAC TEST PLUG-INHJ4-T-AC100V - RELAY PWR 5A 100VAC TEST PLUG-INHJ4-L-T-DC48V - RELAY PWR 5A 48VDC LED/TEST PLUGHJ4-L-T-DC110V - RELAY PWR 5A 110VDC LED/TEST PLGHJ4-L-T-AC48V - RELAY PWR 5A 48VAC LED/TEST PLUGHJ4-L-T-AC24V - RELAY PWR 5A 24VAC LED/TEST PLUGHJ4-L-T-AC200V - RELAY PWR 5A 200VAC LED/TEST PLGHJ4-L-T-AC12V - RELAY PWR 5A 12VAC LED/TEST PLUGHJ4-L-T-AC100V - RELAY PWR 5A 100VAC LED/TEST PLGHJ4-L-DC48V - RELAY PWR 5A 48VDC LED PLUG-INHJ4-L-DC110V - RELAY PWR 5A 110VDC LED PLUG-INHJ4-L-AC48V - RELAY PWR 5A 48VAC LED PLUG-INHJ4-L-AC24V - RELAY PWR 5A 24VAC LED PLUG-INHJ4-L-AC200V - RELAY PWR 5A 200VAC LED PLUG-INHJ4-L-AC12V - RELAY PWR 5A 12VAC LED PLUG-INHJ4-L-AC100V - RELAY PWR 5A 100VAC LED PLUG-INHJ4-DC48V - RELAY POWER 5A 48VDC PLUG-INHJ4-DC110V - RELAY POWER 5A 110VDC PLUG-INHJ4-AC48V - RELAY POWER 5A 48VAC PLUG-INHJ4-AC24V - RELAY POWER 5A 24VAC PLUG-INHJ4-AC200V - RELAY POWER 5A 200VAC PLUG-INHJ4-AC12V - RELAY POWER 5A 12VAC PLUG-INHJ4-AC100V - RELAY POWER 5A 100VAC PLUG-IN255-1700 - RELAY PWR W/TEST 5A 24VDC PLUGIN255-1699 - RELAY PWR W/TEST 5A 12VDC PLUGIN255-1698 - RELAY PWR W/TEST 5A 220/240VAC255-1697 - RELAY PWR W/TEST 5A 120VAC PLUG255-1696 - RELAY PWR LED&TEST 5A 24VDC PLUG255-1695 - RELAY PWR LED&TEST 5A 12VDC PLUG255-1694 - RELAY PWR LED&TEST 5A 220/240VAC255-1693 - RELAY PWR LEDTEST 5A 120VAC PLUG255-1692 - RELAY PWR W/LED 5A 24VDC PLUG-IN255-1691 - RELAY PWR W/LED 5A 12VDC PLUG-IN255-1690 - RELAY PWR W/LED 5A 240VAC PLUGIN255-1689 - RELAY PWR W/LED 5A 120VAC PLUGIN255-1688 - RELAY POWER 5A 24VDC PLUG-IN255-1687 - RELAY POWER 5A 12VDC PLUG-IN255-1686 - RELAY POWER 5A 240VAC PLUG-IN255-1685 - RELAY POWER 5A 120VAC PLUG-IN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1839
HJ4-SFD-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HJ4-SFD-S
Manufacturer:
Panasonic Electric Works
Quantity:
135
HJ
2. Specifications
Notes: In accordance with the Electrical Appliance and Material Safety Law, you cannot exceed a voltage of 150V AC when using the 4 Form C type.
REFERENCE DATA
1-(1). Max. switching capacity (2 Form C type)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
For more information, please inquire.
When using low level loads, contact instability may result depending on conditions of use (switching frequency and ambient conditions, etc.); therefore, please use
the Au plating type.
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
0.5
0.1
10
7
5
1
actual load.
conditions in NOTES.
AC resistive
DC inductive load
L/R=7ms
10
DC resistive load
load
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity
(Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Temperature rise (coil) (at 70 C
Operate time*
Release time*
Shock resistance
Vibration resistance
Mechanical
Electrical (resistive load) (at 20 times/min.)
Conditions for operation, transport and storage*
(Not freezing and condensing at low temperature)
Max. Operating speed
AC inductive load
cos =0.4
AC resistive load
With test button type only
Contact voltage, V
50
100 125 250
2
2
1
Item
Au plating type
Without Au plating type
Between open contacts
Between contact sets
Between contact and coil
Functional
Destructive
Functional
Destructive
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
158
1-(2). Max. switching capacity (4 Form C type)
F)
0.5
0.1
5
3
1
3
AC resistive
DC resistive load
10
load
DC inductive load
L/R=7ms
2 Form C
Max. 50 m (By voltage drop 6 V DC 1A)
Au plating type: Au plating Ag Without Au plating type: Ag
7 A 250V AC
1,750 VA
250V AC, 125V DC
7 A
0.9W 1.2 VA
1mA 1V DC
1mA 5V DC
Min. 100M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 60 C
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 100 m/s
Min. 1,000 m/s
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 s.)
10 to 55 Hz at double amplitude of 1.0 mm
Min. 2 10
Min. 10
Min. 5 10
Ambient temperature: –40 C to +70 C
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)
Approx. 34g
AC inductive load
cos =0.4
Contact voltage, V
5
(7A 250V AC)
50
7
5
140 F
(at 180 times/min.)
(5A 250V AC)
1.20 oz
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
100 125 250
2
(Half-wave pulse of sine wave: 6 ms.)
(By resistive method, nominal coil voltage)
2-(1). Life curve (2 Form C)
Specifications
–40 F to +158 F
500
100
50
10
4 Form C
5 A 250V AC
1,250 VA
5 A
Min. 10
Min. 2 10
0
AC 250V (cos =0.4)
5
1
(5A 250V AC)
5
(3A 250V AC)
2
Load current, A
3
AC 250V (cos =1)
4
5
6
7