DK2A-PS Panasonic Electric Works, DK2A-PS Datasheet
DK2A-PS
Specifications of DK2A-PS
Related parts for DK2A-PS
DK2A-PS Summary of contents
Page 1
... Conforms with FCC Part 68 4. Latching types available 5. Sealed construction allows automatic washing. 6. Sockets are also available 7. Complies with safety standards Complies with Japan Electrical Appliance and Material Safety Law requirements for operating 200 V power supply circuits, and complies with UL, CSA, and TÜV safety standards ...
Page 2
... All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 2 coil latching Part No. DK1a-L2-3V-F DK1a-L2-5V-F DK1a-L2-6V-F DK1a-L2-9V-F DK1a-L2-12V-F DK1a-L2-24V-F DK1a1b-L2-3V DK1a1b-L2-5V DK1a1b-L2-6V DK1a1b-L2-9V DK1a1b-L2-12V DK1a1b-L2-24V DK2a-L2-3V DK2a-L2-5V DK2a-L2-6V DK2a-L2-9V DK2a-L2-12V DK2a-L2-24V Coil resistance Nominal operating 68 F) power 45 125 180 200mW 405 720 2,880 Coil resistance ...
Page 3
Specifications Characteristics Item Arrangement Contact Initial contact resistance, max. Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Rating Max. switching current Nominal operating power Min. switching capacity (Reference value)* Insulation resistance (Initial) ...
Page 4
DK 4-(1). Coil temperature rise (1 Form A) Tested sample: DK1a-12V, 5 pcs. Ambient temperature 10A 100 110 120 130 Coil applied voltage,%V 5-(2). Ambient ...
Page 5
... C 662 F within 3s Soldering depth: 2/3 terminal pitch 2. External magnetic field Since DK relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. For Cautions for Use, see Relay Technical Information. ...
Page 6
... Insulation Min. 1,000 m (at 500 V DC) — resistance Heat resistance 150 C (for 1 hour) Max. continuous 10 A (DK1a-PS, DK1a-PSL2), current 8 A (DK2a-PS, DK2a-PSL2) 2 coil latching type — — 1 Form A 1 Form B 1.2 dia .047 dia 2.54 .100 The above shows 2 coil latching type ...
Page 7
... Notes: 1. Exercise care when removing relays. If greater than necessary force is applied at the socket hooks, deformation may alter the dimensions so that the hook will no longer catch, and other damage may also occur hazardous to use IC chip sockets. ...