G6KU-2F-Y DC3 Omron, G6KU-2F-Y DC3 Datasheet - Page 4

RELAY LATCH DPDT 3VDC SMD

G6KU-2F-Y DC3

Manufacturer Part Number
G6KU-2F-Y DC3
Description
RELAY LATCH DPDT 3VDC SMD
Manufacturer
Omron
Series
G6Kr
Datasheets

Specifications of G6KU-2F-Y DC3

Coil Type
Latching, Single Coil
Coil Current
33mA
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
3VDC
Control On Voltage (max)
2.25 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Form
DPDT
Power Consumption
100 mW
Contact Carry Current
1 A
Maximum Switching Current
1 A
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
3V
Coil Resistance
91ohm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G6KU-2F-YDC3
G6KU-2F-YDC3
G6KU2FYDC3
Z3030
G6K
Engineering Data
4
Shock Malfunction
Shock direction
Maximum Switching Power
Endurance
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Shock is applied in ±X, ±Y, and ±Z di-
rections three times each with and with-
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Switching voltage (V)
AC resistive load
Switching current (A)
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi
Electrical Endurance
(with Must Operate and Must Re
lease Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
mum value in a varying range of operating
power voltage, not a continuous voltage.
Must release
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Must operate voltage
Must release voltage
Electrical Endurance
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
operations)
NO
contact
NC
contact
G6K