G6H-2-DC5 Omron, G6H-2-DC5 Datasheet - Page 3

RELAY MINI PC MNT DPDT 1A 5VDC

G6H-2-DC5

Manufacturer Part Number
G6H-2-DC5
Description
RELAY MINI PC MNT DPDT 1A 5VDC
Manufacturer
Omron
Series
G6Hr
Type
Signal Relayr
Datasheets

Specifications of G6H-2-DC5

Coil Type
Standard
Coil Current
28.1mA
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
5VDC
Control On Voltage (max)
3.75 VDC
Control Off Voltage (min)
0.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Contact Form
2 Form C
Power Consumption
140 mW
Maximum Switching Current
1 A
Contact Rating
0.50 A at 125 VAC, 1 A at 30 VDC
Current, Rating
0.5⁄1 AAC⁄ADC
Diameter, Mounting
0.031 in.
Dielectric Rating
1000 VAC
Dimensions
0.551 in. +⁄- 0.008 in. L x 0.354 in. +⁄- 0.008 in. W x 0.197 in. +⁄- 0.008 in. H
Function
Sensitive
Material, Contact
Ag
Number Of Pins
10
Power, Rating
62.5⁄33 VA⁄W
Standards
UL, CSA, RoHS
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-40 °C
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Relay Construction
Non-Latching
Contact Arrangement
DPDT
Coil Voltage Dc
5V
Voltage Rating (vdc)
110V
Voltage Rating (vac)
125V
Dropout Volt (min)
0.5VDCV
Coil Resistance
178Ohm
Pick-up Voltage (max)
3.38VDC
Maximum Power Rating
33W/62.5VA
Operate Time
3ms
Contact Current Rating
1A
Contact Material
Ag/Au Clad
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
5.4mm
Product Depth (mm)
9.3mm
Product Length (mm)
14.3mm
Operating Temp Range
-40C to 70C
Pin Count
10
Mounting Style
Through Hole
Package / Case
DIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6H2DC5
Z740

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G6H-2-DC5V
Manufacturer:
OMRON
Quantity:
12 000
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
Maximum Switching Capacity
Contact resistance
Operate (set) time
Release (reset) time
Operating
frequency
Insulation resistance
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Mechanical
Electrical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
Electrical Service Life
50 mΩ max. (standard); 60 mΩ max. (surface mount)
3 ms max. (mean value: approx. 2.0 ms)
2 ms max. (mean value: approx. 1.0 ms)
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ max. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same pole
1,500 V 10 x 160 µs between contacts of same polarity (conforms to FCC Part 68)
10 to 55 Hz; 5 mm (0.20 in) double amplitude
10 to 55 Hz; 3 mm (0.12 in) double amplitude
1,000 m/s
500 m/s
Standard: -40° to 70° C (-40° to 158° F); Surface mount: -40° to 85° C (-40° to 185° F)
10% to 85% RH
100 million operations min.
See “Characteristic Data”
Approx. 1.5 g (0.05 oz)
2
(approx. 50 G)
2
(approx. 100 G)
Ambient Temperature vs.
Maximum Voltage (reference only)
Low Signal Relay
G6H
3

Related parts for G6H-2-DC5