ds_61014_en_nf: 040804J
SPECIFICATIONS
Contacts
1].
Coil
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
NF relays are widely acceptable in appli-
cations where small size and high sensi-
tivity are required.
Such applications include: Electronic
equipment, Household applications,
1
2
3
4
5
6
7
Arrangement
Initial contact resistance
(By voltage drop 6 V DC 1 A)
Contact material
Rating,
(resistive load)
Expected life
(min. operations)
Nominal operating power, at 25°C
Max. operating power for continuous duty
MBB types available: 2MBB & 4MBB
(See next page for contact positions.)
Measurement at same location as "Initial breakdown voltage" section
Detection current: 10 mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Detection time: 10µs
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT in catalog.
1]
Movable contact
Stationary contact
Max. switching power
Max. switching voltage
Max. switching current
Mechanical
Electrical
(Resistive)
1.189
30.2
Max.
Typical
2 A 30 V DC
1 A 30 V DC
0.5 A 30 V DC
2C
4C
20.0
.787
10.8
.425
mm
FLATPACK RELAY
2 Form C, 4 Form C
Alarm systems, Office machines, Com-
munication equipment, Measuring equip-
ment, Remote control systems, General
control circuits, Machine tools, Industrial
machinery, etc.
inch
Approx. 300 mW
Approx. 480 mW
Gold-clad silver
Gold-clad silver
at 40°C
220 V AC, DC
60 W 100 VA
Approx. 1 W
2 × 10
50 mΩ
25 mΩ
2 A
10
10
10
8
6
7
104°F
5
FEATURES
1. Flatpack
2. Long seller
Characteristics (at 25°C 77°F, 50% R.H. seal level)
Max. operating speed
Initial insulation resistance*
Electrostatic
capacitance
Initial
breakdown
voltage*
Operate time*
Release time (without diode)*
(at nominal voltage)
Contact bounce
Shock
resistance
Vibration
resistance
Conditions for operation,
transport and storage*
(Not freezing and condens-
ing at low temperature)
Unit weight
2
3
Contact/Contact
Contact/Coil
Contact/Ground
Between open contacts
Between contact sets
Between live parts and ground
Between contacts and coil
Functional*
Destructive*
Functional*
Destructive
(at nominal voltage)
7
NF-RELAYS
4
6
1
5
3
In de-energized
condition
In energized
condition
In de-energized
condition
In energized
condition
Ambient temp.
Humidity
2C
4C
at double amplitude of 0.5 mm
at double amplitude of 1.6 mm
at double amplitude of 3.3 mm
117.6 m/s
at double amplitude of 2 mm
196 m/s
Max. 15 ms (Approx. 10 ms)
29.4 m/s
Max. 10 ms (Approx. 3 ms)
98 m/s
(perpendicular to contact)
(perpendicular to contact)
1,000 M Ω at 500 V DC
Min. 980 m/s
Approx. 15.5 g
Min. 196 m/s
(In contact direction)
(in contact direction)
Min. 29.4 m/s
Min. 98 m/s
Approx. 14 g
–40 ° C to + 65 ° C
–40
Approx. 1.5 ms
5 to 85%R.H.
Approx. 4 pF
Approx. 7 pF
Approx. 6 pF
2
2
1,000 Vrms
1,000 Vrms
1,000 Vrms
2
750 Vrms
{10 G}10 to 55 Hz
{20 G}, 10 to 55 Hz
2
°
{3 G}, 10 to 55 Hz
F to +149
50 cps
{12 G}10 to 55 Hz
2
2
2
pending
CSA
{10 G}
{100 G}
2
.49 oz
{20 G}
.55 oz
{3 G}
°
F
1