G5Q-14 DC5 Omron, G5Q-14 DC5 Datasheet

RELAY PWR SPDT 5VDC PCB

G5Q-14 DC5

Manufacturer Part Number
G5Q-14 DC5
Description
RELAY PWR SPDT 5VDC PCB
Manufacturer
Omron
Series
G5Qr
Datasheets

Specifications of G5Q-14 DC5

Relay Type
General Purpose
Coil Type
Standard
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
277VAC, 30VDC - Max
Coil Current
80mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.75 VDC
Turn Off Voltage (min)
0.25 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 125VAC
Control On Voltage (max)
3.75 VDC
Control Off Voltage (min)
0.25 VDC
Coil Voltage Vdc Nom
5V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
63ohm
Contact Configuration
SPDT
Current, Rating
10 A (NO), 3 A (NC)
Function
General Purpose
Number Of Pins
5
Power, Rating
1250 VA⁄150 W (NO), 375 VA⁄90 W (NC)
Standards
UL, CSA, RoHS, VDE
Termination
Through Hole
Voltage, Control
5 VDC
Voltage, Rating
125 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G5Q-14DC5
G5Q-14DC5
G5Q14DC5
Z2929
Compact, Single-pole, 10-A Switching
PCB Relays
Ordering Information
Model Number Legend:
1. Number of Poles
2. Contact Form
PCB Relay
Contact form
SPST-NO
SPDT
G5Q-@@@
RoHS Compliant
Compact, SPST-NO and SPDT relays.
Excellent switching performance for a variety of
loads.
Withstand impulse rating of 8,000 V between the
coil and contacts.
UL class F coil insulation on all models.
UL, CSA, and VDE approved.
1:
None: SPDT
A:
Enclosure rating
1 2 3
1 pole
SPST-NO
Classification
5 VDC
9 VDC
12 VDC
24 VDC
5 VDC
9 VDC
12 VDC
24 VDC
Rated coil voltage
Flux protection
G5Q-1A
G5Q-1
Model
Standard models
3. Enclosure Rating
5 VDC
9 VDC
12 VDC
24 VDC
5 VDC
9 VDC
12 VDC
24 VDC
Rated coil voltage
None: Flux protection
4:
Fully sealed
Fully sealed
G5Q-1A4
G5Q-14
Model
G5Q
1

Related parts for G5Q-14 DC5

G5Q-14 DC5 Summary of contents

Page 1

... G5Q-@@@ Number of Poles 1: 1 pole 2. Contact Form None: SPDT A: SPST-NO Standard models Flux protection Model Rated coil voltage G5Q-1A 5 VDC 9 VDC 12 VDC 24 VDC G5Q-1 5 VDC 9 VDC 12 VDC 24 VDC 3. Enclosure Rating None: Flux protection 4: G5Q Fully sealed Model G5Q-1A4 G5Q-14 Fully sealed 1 ...

Page 2

... A (NO)/3 A (NC) at 125 VAC, resistive load 100,000 operations (NO)/3 A (NC) at 250 VAC (NO)/3 A (NC VDC, resistive load 50,000 operations 125 VAC (900 operations per hour VDC (with no icing or condensation 85% Approx. 6.5 g G5Q Must-release Max. voltage Power voltage (V) (V) consumption (mW) 5% min. of 190% of rated Approx ...

Page 3

... DC resistive load (NO) AC resistive load (NC) DC resistive load (NC 100 1000 Switching voltage (V) Contact ratings Number of test operations 6,000 6,000 10,000 6,000 6,000 Contact ratings Number of test operations 10,000 Ambient Temperature vs. Maximum Voltage 200 180 160 140 120 100 100 120 Ambient temperature ( C) G5Q 3 ...

Page 4

... Do not use the G5Q for applications in automotive vehicles (in- cluding motorcycles). • Consult your OMRON sales representative when considering use of the G5Q in any of the following applications, and be sure to exchange specifications documents. Also, allow a margin of safety in ratings and performance, use safety circuits to minimize danger in the event of malfunction, and provide safety measures, such as redundant designs ...

Related keywords