G4B-112T1-FD-C-US-RPAC240 Omron, G4B-112T1-FD-C-US-RPAC240 Datasheet - Page 2

RELAY POWER SPDT 240VAC QC

G4B-112T1-FD-C-US-RPAC240

Manufacturer Part Number
G4B-112T1-FD-C-US-RPAC240
Description
RELAY POWER SPDT 240VAC QC
Manufacturer
Omron
Series
G4Br
Datasheet

Specifications of G4B-112T1-FD-C-US-RPAC240

Relay Type
General Purpose
Coil Type
Standard
Contact Form
SPDT (1 Form C)
Contact Rating (current)
25A
Switching Voltage
250VAC, 125VDC - Max
Coil Current
5.4mA
Coil Voltage
240VAC
Turn On Voltage (max)
192 VAC
Turn Off Voltage (min)
72 VAC
Mounting Type
Chassis Mount
Termination Style
Quick Connect - .187"/.250"
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
25A @ 220VAC
Control On Voltage (max)
192 VAC
Control Off Voltage (min)
72 VAC
Coil Voltage Vac Nom
240V
Contact Current Max
25A
Contact Voltage Ac Nom
220V
Contact Voltage Dc Nom
24V
Contact Configuration
SPDT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G4B112T1FDCUSRPAC240
2
G4B
AC
DC
Note: The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with tolerances of 10% for DC rated
Note: Data shown are of initial value.
Rated
voltage
(V)
6
12
24
50
100
120
240
Rated
voltage
(V)
6
12
24
48
100
110
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
COIL DATA
CHARACTERISTICS
current and +15%, -20% for AC rated current, and 15% for rated coil resistance.
Rated current
(mA)
50Hz
254
126.50
63
30.50
15
12.60
6.30
Rated current
(mA)
200
89
50
25
12
9
Mechanical
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Mechanical
Electrical
60Hz
217
108
54
26
13
10.80
5.40
Coil
resistance
( )
Coil
resistance
( )
30
135
480
1,920
8,300
12,300
30 m
20 ms max.
20 ms max.
1,800 operations/hour
1,800 operations/hour (under rated load)
100 M
2,000 VAC 50/60 Hz for 1 minute (1,000 VAC between non-continuous contacts)
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Approx. 100 G
Approx. 20 G
-10 to 55 C (14 to 131 F)
35% to 85% RH
10 million operations min. (at 18,000 operations/hour)
See “Characteristic Data”
Approx. 44 g (1.55 oz)
max.
min (at 500 VDC)
Pick-up
voltage
% of rated voltage
80% max.
Pick-up
voltage
% of rated voltage
80% max.
Dropout
voltage
30% min.
Dropout
voltage
10% min.
Maximum
voltage
110% max.
Maximum
voltage
110% max.
Power
consumption
(VA,W)
Approx.1.30 VA
Power
consumption
(VA,W)
Approx. 1.20 W
G4B