2966184 Phoenix Contact, 2966184 Datasheet - Page 2

PLC RELAY SPDT 24VAC/DC

2966184

Manufacturer Part Number
2966184
Description
PLC RELAY SPDT 24VAC/DC
Manufacturer
Phoenix Contact
Series
-r
Datasheets

Specifications of 2966184

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
11mA
Coil Voltage
24VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
6A @ 250VAC
Contact Rating
6 A at 250 V
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
140 W
Contact Material
Silver Tin Oxide
Brand/series
PLC-RSC/RSP
Function
PLC
Phoenix Part Number
PLC-RSC-24UC/21
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Operate Time
6ms
Release Time
15ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-25°C ~ 60°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
PLC-RSC-24UC/21
PLC-RSC- 24UC/21
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2966184
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Typical response time
Typical release time
Operating voltage display
Protective circuit
Contact side
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Maximum inrush current
Min. switching current
Limiting continuous current
Interrupting rating (ohmic load) max.
General data
Width
Height
Depth
Test voltage relay winding/relay contact
Ambient temperature (operation)
Ambient temperature (storage/transport)
Operating mode
Mechanical service life
Inflammability class acc. to UL 94
Name
Standards/regulations
Order No.: 2966184
6 ms
15 ms
Yellow LED
Bridge rectifier Bridge rectifier
Single contact, 1-PDT
AgSnO
250 V AC/DC (The separating plate PLC-ATP should be installed
for voltages larger than 250 V (L1, L2, L3) between identical
terminal blocks in adjacent modules. Potential bridging is then
carried out with FBST 8-PLC... or ...FBST 500...)
5 V (at 100 mA)
(on request)
10 mA (at 12 V)
6 A
140 W (at 24 V DC)
20 W (for 48 V DC)
18 W (for 60 V DC)
23 W (for 110 V DC)
40 W (for 220 V DC)
1500 VA (for 250 V AC)
6.2 mm
80 mm
94 mm
4 kV AC (50 Hz, 1 min.)
-40 °C ... 60 °C
-40 °C ... 85 °C
100% operating factor
2 x 10
V0
Standards/regulations
IEC 60664
EN 50178
IEC 62103
7
cycles
Jun 12, 2011
Page 2 / 6

Related parts for 2966184