2966197 Phoenix Contact, 2966197 Datasheet - Page 3

PLC RELAY SPDT 120VAC/DC

2966197

Manufacturer Part Number
2966197
Description
PLC RELAY SPDT 120VAC/DC
Manufacturer
Phoenix Contact
Series
-r
Datasheets

Specifications of 2966197

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
3.5mA
Coil Voltage
120VAC/DC
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
6A @ 250VAC
Contact Rating
6 A at 250 V
Contact Termination
PCB
Mounting Style
PCB
Power Consumption
140 W
Contact Material
Silver Tin Oxide
Brand/series
PLC-RSC/RSP
Current, Rating
6 A
Function
PLC
Material, Contact
AgSnO
Phoenix Part Number
PLC-RSC-120UC/21
Power, Rating
23 W
Standards
cULus, UL, RoHS
Temperature, Operating, Maximum
55 °C
Temperature, Operating, Minimum
-20 °C
Termination
Screw
Voltage, Control
120 VAC
Voltage, Rating
250 VAC/VDC
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Operate Time
6ms
Release Time
15ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-25°C ~ 55°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control On Voltage (max)
-
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
PLC-RSC-120UC/21
3
101780_en_02
Accessories
Description
Insulating plate
For additional accessories such as power terminal blocks and plug-in bridges, please refer to the INTERFACE catalog or www.phoenixcontact.com.
Input Data
Nominal input voltage
Permissible range (with reference to U
Typical input current at U
Typical response time at U
Typical release time at U
Input circuit
Output Data
Contact type
Contact material
Maximum switching voltage
Minimum switching voltage
Limiting continuous current
Maximum inrush current
Minimum switching current
Maximum shutdown power
Minimum switching power
General Data
Impulse voltage withstand level
Ambient temperature range
Nominal operating mode
Inflammability class according to UL 94 (housing)
Mechanical service life
Operation
Storage/transport
1
1
2
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
If the specified maximum values are exceeded, the gold coating will be damaged. In subsequent operation, the
apply. This can then result in reduced service life, similar to dedicated power contacts.
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
Technical Data
The PLC-ATP BK insulating plate should be used in the following cases: always fit at the start and end of a PLC terminal strip for voltages
greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules (FBST 8-PLC... or FBST 500... can be used for
potential bridging) and for safe isolation between adjacent modules.
1
N
N
N
N
)
110 V DC
220 V DC
250 V AC
24 V DC
48 V DC
60 V DC
Type
PLC-ATP BK
4 kV, 50 Hz, 1 min.
-25°C ... 60°C (230 V type -25°C ... 55°C)
-40°C ... 85°C
100% operating factor
V0
2 x 10
against polarity
wheeling diode
reversal, free-
...24DC...
Yellow LED,
protection
24 V DC
30 A (for AC 15 operation)
7
9 mA
4 ms
8 ms
cycles
Ohmic load τ = 0 ms
250 V AC/DC
PLC-...21
12 V AC/DC
1500 VA
120 mW
AgSnO
10 mA
140 W
20 W
18 W
23 W
40 W
See "Operating Voltage Ranges" on page 5
6 A
11 mA/8.5 mA
...24UC...
24 V AC/DC
2
15 ms
6 ms
Single contact, SPDT
Yellow LED, bridge rectifier
AgSnO contact values given here will
Order No.
2966841
...120UC...
3.5 mA/3 mA
120 V AC/
110 V DC
15 ms
6 ms
Ohmic load τ = 0 ms
30 V AC/36 V DC
PLC-...21AU
PHOENIX CONTACT
AgSnO + 5 μA
100 mV
50 mA
50 mA
10 μW
1.2 W
1 mA
Pcs./Pck.
25
PLC-RS…/21
...230UC...
230 V AC/
220 V DC
1
15 ms
3 mA
7 ms
3

Related parts for 2966197