DK2A-L2-24V Panasonic Electric Works, DK2A-L2-24V Datasheet - Page 3

no-image

DK2A-L2-24V

Manufacturer Part Number
DK2A-L2-24V
Description
RELAY LATCHING 8A 24VDC PCB
Manufacturer
Panasonic Electric Works
Series
DKr
Datasheet

Specifications of DK2A-L2-24V

Relay Type
General Purpose
Contact Form
DPST (2 Form A)
Contact Rating (current)
8A
Switching Voltage
250VAC
Coil Type
Latching, Dual Coil
Coil Current
8.3mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPST (2 Form A)
Contact Rating @ Voltage
8A @ 250VAC
Control On Voltage (max)
16.8 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Other names
255-1603

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DK2A-L2-24V
Manufacturer:
Panasonic
Quantity:
12 000
DK
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
REFERENCE DATA
1-(1). Maximum operating power (1 Form A)
2-(2). Life curve
(1 Form A 1 Form B, 2 Form A)
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Characteristics
1,000
100
100
0.1
10
10
*2. Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
1
1
0
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
actual load.
conditions in NOTES.
DC inductive load
1
AC inductive load
2
(L/R = 7 ms)
(cos = 0.4)
3
10
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage*
Temperature rise (coil) (at 65 C
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock resistance
Vibration resistance
Mechanical
Electrical
Conditions for operation, transport and storage*
Max. operating speed (at rated load)
Contact voltage, V
Contact current, A
4
250 V AC resistive load
30 V DC resistive load
5
6
AC resistive load
2
100
(Initial)
DC resistive
load
7
8
9 10
1,000
Between open contacts
Between contact and coil
between contacts and coil
Functional
Destructive
Functional
Destructive
Item
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
149
68
68
1-(2). Maximum operating power
(1 Form A 1 Form B, 2 Form A)
3-(1). Operate/Release time (1 Form A)
Tested sample: DK1a-24V, 5 pcs.
F)
F)
F)
0.1
10
1
5
1
9
8
7
6
5
4
3
2
1
0
80
DC inductive load
3
AC inductive load
90
(L/R = 7 ms)
Release time
(with diode)
Operate time
Release time
10 A 250 V AC, 10 A 30 V DC
Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Max. 40 C (By resistive method, nominal voltage applied to the coil; max. switching current)
(cos = 0.4)
10
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Coil applied voltage,%V
Au-flashed AgSnO
10
Contact voltage, V
250 V AC, 125 V DC
Approx. 5 g
2,500VA, 300 W
110
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Min. 98 m/s
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
1 Form A
AC resistive load
10 A
DC resistive
10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 s.)
100
120
load
Max.
Max.
x
Min.
Min.
Max.
Min.
x
x
Min. 10
.18 oz
Ambient temperature: –40 C to +65 C
130
Min. 980 m/s
Max. 10 ms (Approx. 5 ms) [10 ms (Approx. 5 ms)]
2
2
Max. 8 ms (Approx. 3 ms) [10 ms (Approx. 3 ms)]
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
type
5
1,000
Max. 30 m (By voltage drop 6 V DC 1A)
140
(resistive load, at 20 times/min., at rated capacity)
10 to 55 Hz at double amplitude of 3 mm
Min. 5 10
8 A 250 V AC,8 A 30 V DC
2
(Half-wave pulse of sine wave: 6 ms.)
250 V AC, 125 V DC
1 Form A 1 Form B
Approx. 6 g
2,000 VA, 240 W
10m A 5 V DC
Specifications
20 times/min.
2-(1). Life curve (1 Form A)
3-(2). Operate/Release time
(1 Form A 1 Form B, 2 Form A)
Tested sample: DK1a1b-12V, 5 pcs.
7
10,000 V
200 mW
(at 300 times/min.)
1,000
8 A
100
10
1
9
8
7
6
5
4
3
2
1
0
0
.21 oz
250 V AC inductive load (cos = 0.4)
30 V DC inductive load (L/R = 7 ms)
80
Operate time
Au-flashed AgNi type
1
2
90
–40 F to +149
Release time
3
Coil applied voltage,%V
10
250 V AC resistive load
30 V DC resistive load
Contact current, A
Release time
(with diode)
4
8 A 250 V AC,8 A 30 V DC
5
110
250 V AC, 125 V DC
Approx. 6 g
2,000 VA, 240 W
6
F,
2 Form A
120
7
Max.
Min.
Max.
Min.
Max.
Min.
x
x
x
8 A
8
130
.21 oz
9 10
140

Related parts for DK2A-L2-24V