ADJ23105 Panasonic Electric Works, ADJ23105 Datasheet - Page 4

no-image

ADJ23105

Manufacturer Part Number
ADJ23105
Description
RELAY PWR LATCH FLUX 16A 5V PCB
Manufacturer
Panasonic Electric Works
Series
ADJr
Datasheets

Specifications of ADJ23105

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
16A
Switching Voltage
250VAC - Max
Coil Type
Latching, Dual Coil
Coil Current
50mA
Coil Voltage
5VDC
Turn On Voltage (max)
3.5 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
16A @ 250VAC
Control On Voltage (max)
3.5 VDC
Brand/series
ADJ Series
Current, Rating
16 A
Function
Latching
Power, Rating
4000 VA
Standards
cULus, VDE
Termination
Solder
Voltage, Control
5 VDC
Voltage, Rating
250 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Control Off Voltage (min)
-
Lead Free Status / Rohs Status
RoHS Compliant part
DJ (ADJ)
RATING
1. Coil data
1) Single side stable
2) 1 coil latching
3) 2 coil latching
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Nominal coil voltage
Nominal coil voltage
Nominal coil voltage
Characteristics
*2. Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
*3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES.
*4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
12V DC
24V DC
48V DC
5V DC
6V DC
5V DC
6V DC
5V DC
6V DC
actual load.
conditions in NOTES.
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Surge breakdown
voltage*
Temperature rise (coil) (at 70 C
Operate time [Set time] (at 20 C
Release time [Reset time] (at 20 C
Shock resistance
Vibration resistance
Mechanical
Electrical (Resistive load)*
Conditions for operation, transport and storage*
75%V or less of nominal
70%V or less of nominal
70%V or less of nominal
Pick-up voltage
2
(at 20 C
voltage (Initial)
(at 20 C
voltage (Initial)
(at 20 C
voltage (Initial)
(Initial)
Set voltage
Set voltage
68
68
68
F)
F)
F)
Between open contacts
Between contact and coil
Between contact and coil
Functional
Destructive
Functional
Destructive
Item
3
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
(at 20 times/min.)
10%V or more of nominal
158
70%V or less of nominal
70%V or less of nominal
68
68
F)
Drop-out voltage
F)
(at 20 C
voltage (Initial)
(at 20 C
voltage (Initial)
(at 20 C
voltage (Initial)
Reset voltage
Reset voltage
F)
1
68
68
68
4
F)
F)
F)
1 Form C, 1 Form A, 1 Form B, 1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B
Max. 100 m (By voltage drop 6 V DC 1A)
AgSnO
Au-flashed AgSnO
16 A 250V AC (1 Form C, 1 Form A, 1 Form B),
10 A 250V AC (2 Form C, 2 Form A, 2 Form B, 1 Form A 1 Form B)
4,000 V A
250V AC
16 A (1 Form C, 1 Form A, 1 Form B),
10 A (1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B)
150mW (1 coil latching), 250mW (Single side stable, 2 coil latching)
100mA 5 V DC
Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
4,000 Vrms for 1min. (Detection current: 10mA.)
Min. 10,000 V
Max. 55 C (By resistive method, nominal voltage applied to the coil, max. switching current.)
Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Min. 200 m/s
Min. 1,000 m/s
10 to 55 Hz at double amplitude of 2 mm (Detection time: 10 s.)
10 to 55 Hz at double amplitude of 3 mm
Min. 5 10
Min. 10
Min. 10
Ambient temperature: –40 C to +70 C
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Approx. 14 g
5
5
2
[ 10%] (at 20 C
[ 10%] (at 20 C
[ 10%] (at 20 C
type (1 Form C, 1 Form A, 1 Form B),
(at 16A 250V AC): 1 Form C, 1 Form A, 1 Form B
(at 10A 250V AC): 2 Form C, 2 Form A, 2 Form B, 1 Form A 1 Form B
6
(at 180 times/min.)
Coil resistance
Coil resistance
Coil resistance
2
.49 oz
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
2
15,360
2,304
9,216
3,840
2,304
9,216
(Half-wave pulse of sine wave: 6 ms.)
100
144
576
167
240
960
100
144
576
2
type (1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B)
68
68
68
F)
F)
F)
Nominal operating power
Nominal operating power
Nominal operating power
Specifications
–40 F to +158 F
250mW
150mW
250mW
130%V of nominal voltage
130%V of nominal voltage
130%V of nominal voltage
Max. applied voltage
Max. applied voltage
Max. applied voltage
(at 20 C
(at 20 C
(at 20 C
68
68
68
F)
F)
F)

Related parts for ADJ23105