MY4H-0-AC110/120 Omron, MY4H-0-AC110/120 Datasheet - Page 2

no-image

MY4H-0-AC110/120

Manufacturer Part Number
MY4H-0-AC110/120
Description
RELAY GP 4PDT 3A 110/120VAC
Manufacturer
Omron
Series
MY4Hr
Datasheet

Specifications of MY4H-0-AC110/120

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
125VAC, 125VDC - Max
Coil Type
Standard
Coil Current
9.2mA
Coil Voltage
120VAC
Turn On Voltage (max)
96 VAC
Turn Off Voltage (min)
36 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
3A @ 110VAC
Control On Voltage (max)
96 VAC
Control Off Voltage (min)
36 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MY4H0AC110120
Contact Ratings
■ Characteristics
256
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Contact resistance
Operate time
Release time
Max. operating
frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Hermetically Sealed Relay
Mechanical
Electrical
Destruction
Malfunction
Destruction
Malfunction
Operating
Storage
Resistive
p.f.=1
Inductive
p.f.=0.4
L/R-7 ms
MY4H
Ag alloy
110 VAC, 3 A
24 VDC, 3A
110 VAC, 0.8 A
24 VDC, 1.5 A
3 A
125 VAC, 125 VDC
3 A
330 VA
72 W
50 mΩ max.
20 ms max.
20 ms max.
18,000 operations/hr
1,800 operations/hr (under rated load)
100 MΩ min. (at 500 VDC)
1,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of different polarity
700 VAC, 1 min between contacts of same polarity
10 to 55 Hz, 0.5 mm single amplitude
10 to 55 Hz, 0.5 mm single amplitude
1,000 m/s
When energized: 200 m/s
When not energized: 200 m/s
Mechanical:
Electrical:
-25 to 60°C
-25 to 60°C
5% to 85%
Approx. 50 g
2
5,000,000 operations
50,000 operations
2
2