MY4-02 DC6 Omron, MY4-02 DC6 Datasheet - Page 5

RELAY GP 4PDT 3A 6VDC

MY4-02 DC6

Manufacturer Part Number
MY4-02 DC6
Description
RELAY GP 4PDT 3A 6VDC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY4-02 DC6

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Standard
Coil Current
150mA
Coil Voltage
6VDC
Turn On Voltage (max)
4.8 VDC
Turn Off Voltage (min)
0.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
3A @ 220VAC
Control On Voltage (max)
4.8 VDC
Control Off Voltage (min)
0.6 VDC
Contact Rating
3 A at 250 VAC, 30 VDC
Contact Termination
Solder Pin
Mounting Style
Snap In
Power Consumption
0.9 W
Coil Resistance
39.8 Ohms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MY4-02DC6
MY402DC6
MY
■ CHARACTERISTICS
Non-latching
Latching
Note: Data shown are of initial value.
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Mechanically
Under rated load
Single contact type
Bifurcated contact type
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Mechanically
Electrically
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
50 mΩ max.
20 ms max.
20 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
Unsealed: 2,000 VAC, 50/60 Hz for 1 minute
Sealed:
Hermetically sealed: 1,000 VAC, 50/60 Hz for 1 minute
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between non-continuous contacts
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
Unsealed: -55° to 70°C (-67° to 158°F)
Sealed:
Hermetically sealed: 25° to 60°C (77° to 140°F)
35% to 85% RH
Single contact type:
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Bifurcated contact type:
AC: 50 million operations min.
DC: 20 million operations min. (5 million operations for the sealed/hermetically
sealed types) (at operating frequency of 1,800 operations/hour)
See “Characteristic Data”
Sealed/unsealed: Approx. 35 g (1.23 oz)
Hermetically sealed: Approx. 50 g (1.76 oz)
50 mΩ max.
AC: 30 ms max.; DC: 15 ms max.
AC: 30 ms max.; DC: 15 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity, and between
set and reset coils
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
-55° to 70°C (-67° to 158°F)
45% to 85% RH
100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 30 g (1.06 oz)
2
2
(approx. 20 G)
(approx. 20 G)
2
2
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
1,500 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
700 VAC, 50/60 Hz for 1 minute between contacts of same polarity
-55° to 60°C (-67° to 140°F)
(approx. 100 G)
(approx. 100 G)