G6C-2117P-US-DC8 Omron, G6C-2117P-US-DC8 Datasheet - Page 3

POWER PCB RELAY

G6C-2117P-US-DC8

Manufacturer Part Number
G6C-2117P-US-DC8
Description
POWER PCB RELAY
Manufacturer
Omron
Series
G6Cr

Specifications of G6C-2117P-US-DC8

Relay Type
General Purpose
Contact Form
DPST-NO/NC (1 Form A and B)
Contact Rating (current)
8A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
25mA
Coil Voltage
8VDC
Turn On Voltage (max)
5.6 VDC
Turn Off Voltage (min)
0.8 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
DPST-NO/NC (1 Form A and B)
Contact Rating @ Voltage
8A @ 250VAC
Control On Voltage (max)
5.6 VDC
Control Off Voltage (min)
0.8 VDC
Coil Voltage Vdc Nom
8V
Contact Current Max
8A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
720ohm
Contact Configuration
SPST-NO / SPST-NC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G6C2117PUSDC8
5.9 Temperature rise
5.10 Vibration
5.11 Shock
5.7 Insulation resistance
5.8 Dielectric strength(leakage current3mA 50/60Hz for a minute)
(1)Mechanical durability
(1)Between coil terminals and contact terminals 1000 MΩ MIN.
(2)Between non-continuous current-carrying contact terminals
(3)Between contact terminals of the same polarity
(4)Between set coil and reset coil
(5)Between current-carrying terminal and exposed non-current currying
(1)Between coil terminals and contact terminals
(2)Between non-continuous current-carrying terminals
(3)Between contact terminals of the same polarity
(4)Between set coil and reset coil
(5)Between current-carrying terminal and exposed non-current carrying
(1) Coil
(2) Contact
(1) Mechanical durability
(2) Malfunction durability
metal part.
metal part.
(When energized)
(When not energized) Contacts must not open for 1ms
or set status
or reset status
500VDC
(by the coil resistance method)at.---℃
(by the thermometer method)at.---℃
50℃ MAX.
Applied voltage of coil:100%
of rated voltage---Hz
Carry current of contact8A
65℃ MAX.
Applied voltage of coil:100%
of rated voltage ---Hz
Carry current of contact8A
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a variable vibration of
0.75mm single amplitude(1.5mm double amplitude)
at a vibration frequency of 10-55-10 Hz
in each direction for 2 hours.
Contacts must not open for 1ms
or longer after the relay is subjected to a
variable vibration of 0.75mm single amplitude
(1.5mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
or longer after the relay is subjected to a
variable vibration of 0.75mm single amplitude
(1.5mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a shock of 1000m/s
in each direction 3 times.
AC2000 V
AC2000 V
AC1000 V
AC---- V
AC---- V
1000 MΩ MIN.
1000 MΩ MIN.
---- MΩ MIN.
---- MΩ MIN.
Spec No:G6C-0705007A
P. 3

Related parts for G6C-2117P-US-DC8