G2R-1-DC12 Omron, G2R-1-DC12 Datasheet - Page 5

RELAY PWR SPDT 10A 12VDC PCB

G2R-1-DC12

Manufacturer Part Number
G2R-1-DC12
Description
RELAY PWR SPDT 10A 12VDC PCB
Manufacturer
Omron
Series
G2Rr

Specifications of G2R-1-DC12

Relay Type
General Purpose
Coil Resistance
275 Ohms
Contact Form
SPDT (1 Form C)
Contact Rating (current)
10A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
43.6mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.8 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPDT (1 Form C)
Contact Rating @ Voltage
10A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.8 VDC
Contact Rating
10 A
Contact Termination
Solder Pin
Mounting Style
Through Hole
Power Consumption
530 mW
Contact Material
Silver Alloy
Coil Voltage Vdc Nom
12V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPDT
Current, Rating
10 A
Function
Power
Number Of Pins
5
Power, Rating
2500⁄300 VA⁄W
Standards
UL, CSA, VDE, CE
Termination
Through Hole
Voltage, Control
12 VDC
Voltage, Rating
380 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
G2R-1-DC12
G2R1DC12
Z2839

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G2R-1-DC12V
Manufacturer:
OMRON
Quantity:
12 000
Company:
Part Number:
G2R-1-DC12V
Quantity:
5 655
G2R
PCB/Fully sealed Relays
Note:
Latching Relays
Note:
I
Standard Relays
Note:
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 8 A
Max. switching power
Failure rate
(reference value)
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A
Max. switching power
Failure rate
(reference value)
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Characteristics
P level:
P level:
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Item
Item
l
l
60
60
= 0.1 x 10
= 0.1 x 10
1 pole
Resistive load
(cos = 1)
8 A at 250 VAC;
8 A at 30 VDC
8 A
2,000 VA,
240 W
100 mA at 5 VDC
1 pole
Resistive load
(cos = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
1,250 VA, 150 W
100 mA at 5 VDC
–6
-6
/operation
/operation
30 m
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 200 m/s
Mechanical: AC coil: 10,000,000 operations min.;
DC coil:
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g (plug-in terminal: approx. 20 g)
max. (high-capacity type: 100 m
Inductive load
(cos = 0.4;
L/R = 7 ms)
6 A at 250 VAC;
4 A at 30 VDC
1,500 VA,
120 W
General-purpose (single contact)
min. (at 500 VDC)
20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
1,800 operations/hr (under rated load)
Inductive load
(cos = 0.4;
L/R = 7 ms)
3.5 A at 250 VAC;
2.5 A at 30 VDC
875 VA, 75 W
2
1 pole
when energized; 100m/s
2
2 poles
Resistive load
(cos = 1)
4 A at 250 VAC;
4 A at 30 VDC
4 A
380 VAC, 125 VDC
4 A
1,000 VA,
120 W
10 mA at 5 VDC
max.)
Inductive load
(cos = 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2.5 A at 30 VDC
375 VA,
75 W
2 poles
Resistive load
(cos = 1)
3 A at 250 VAC;
3 A at 30 VDC
3 A
380 VAC, 125 VDC
3 A
750 VA, 90 W
10 mA at 5 VDC
2
when no energized
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
max.
1 pole
Resistive load
(cos = 1)
5 A at 250 VAC;
5 A at 30 VDC
5 A
380 VAC, 125 VDC
5 A
1,250 VA,
150 W
1 mA at 5 VDC
2 poles
Bifurcated contact
Inductive load
(cos = 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2 A at 30 VDC
375 VA, 60 W
Inductive load
(cos = 0.4;
L/R = 7 ms)
2 A at 250 VAC;
3 A at 30 VDC
500 VA,
90 W
G2R
5