G5NB-1A-E DC12 Omron, G5NB-1A-E DC12 Datasheet - Page 2

RELAY PWR SPST-NO 5A 12VDC PCB

G5NB-1A-E DC12

Manufacturer Part Number
G5NB-1A-E DC12
Description
RELAY PWR SPST-NO 5A 12VDC PCB
Manufacturer
Omron
Series
G5NB-Er
Datasheet

Specifications of G5NB-1A-E DC12

Relay Type
General Purpose
Contact Form
SPST-NO (1 Form A)
Contact Rating (current)
5A
Switching Voltage
250VAC, 30VDC - Max
Coil Type
Standard
Coil Current
16.7mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
SPST-NO (1 Form A)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
9 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G5NB-1A-E DC12BYOMZ
G5NB-1A-EDC12
G5NB1AEDC12
G5NB1AEDC12BYOMZ
Z2772
Specifications
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
■ Contact Ratings
■ Characteristics
Note: 1. The data shown above are initial value.
116
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
Power consumption
Rated load (resistive, p.f.= 1)
Max. switching voltage
Rated carry current
Max. switching current
Max. switching power
Contact resistance (see note 2)
Operate time
Release time
Insulation resistance (see note 3)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy
Minimum permissible load
(reference value) (see note 4)
Ambient temperature
Ambient humidity
Weight
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method
3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
4. This value is for a switching frequency of 120 operations/minute. (P level: λ
PCB Relay
Load
G5NB
5 VDC
40.0 mA
125 Ω
75% of rated voltage (max.)
10% of rated voltage (min.)
Standard: 180% of rated voltage (at 23°C)
High-capacity: 170% of rated voltage (at 23°C)
Approx. 200 mW
3 A at 125 VAC
3 A at 30 VDC
250 VAC, 30 VDC
3 A
3 A
375 VA, 90 W
100 mΩ max.
10 ms max.
10 ms max.
1,000 MΩ min. (at 500 VDC)
4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
10,000 V (1.2 x 50 μs) between coil and contacts
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating: –40°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 4 g
5 VDC, 10 mA
All electrical load ratings are resistive, with operation frequency = 1,800 operations/hour.
12 VDC
16.7 mA
720 Ω
Standard
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s
100 m/s
5,000,000 operations min. (18,000 operations/hour)
200,000 operations minimum:
High-capacity
5 A at 125 VAC
3 A at 30 VDC
100,000 operations minimum:
High-capacity
5 A at 250 VAC
2
60
(approx. 10 G)
2
= 0.1 x 10
(approx. 100 G)
18 VDC
11.1 mA
1,620 Ω
-6
operations)
5 A at 250 VAC
3 A at 30 VDC
250 VAC, 30 VDC
5A
5A (AC load,) 3A (DC load)
1,250 VA, 90 W
Standard
3 A at 125 VAC
3 A at 30 VDC
High-capacity
24 VDC
8.3 mA
2,880 Ω

Related parts for G5NB-1A-E DC12