SF4D-DC24V Panasonic Electric Works, SF4D-DC24V Datasheet - Page 4

RELAY SAFETY 6A 24VDC PCMNT 8PST

SF4D-DC24V

Manufacturer Part Number
SF4D-DC24V
Description
RELAY SAFETY 6A 24VDC PCMNT 8PST
Manufacturer
Panasonic Electric Works
Series
SFr
Type
Safety Relayr
Datasheets

Specifications of SF4D-DC24V

Relay Type
Safety
Contact Form
8PST (4 Form A, 4 Form B)
Contact Rating (current)
6A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
20.8mA
Coil Voltage
24VDC
Turn On Voltage (max)
14.4 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
8PST (4 Form A, 4 Form B)
Contact Rating @ Voltage
6A @ 250VAC
Control On Voltage (max)
14.4 VDC
Control Off Voltage (min)
3.6 VDC
Brand/series
SF Series
Current, Rating
6 A
Function
Safety
Material, Contact
Gold-Flashed Silver Alloy
Number Of Pins
18
Resistance, Coil
1.152 Ohms
Standards
cULus, TUV, CSA
Temperature, Operating
-40 to +70 °C
Termination
Solder
Voltage, Breakdown
2500 V (RMS) (Between Contacts and Coil)
Voltage, Control
24 VDC
Voltage, Rating
380 VAC
Weight
1.66 Oz. (Approx.)
Relay Construction
Non-Latching
Contact Arrangement
4PST-NO/4PST-NC
Coil Voltage Dc
24V
Voltage Rating (vdc)
30V
Voltage Rating (vac)
440V
Dropout Volt (min)
3.6VDCV
Coil Resistance
1.152kohm
Pick-up Voltage (max)
18VDC
Maximum Power Rating
180W/1.5KVA
Operate Time
30ms
Contact Current Rating
6A
Contact Material
Silver Tin Oxide/Gold Flash
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Unsealed
Product Height (mm)
16.5mm
Product Depth (mm)
33mm
Product Length (mm)
53.3mm
Operating Temp Range
-40C to 70C
Pin Count
18
Mounting Style
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1441

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
SF4D-DC24V
Quantity:
29
SF4D
Operation of forcibly guided contacts, Type B
If an outer contact should weld, then the forced operated inner contacts driven by the actuator remain open.
The rotating armature remains free to move.
The unaffected contact pairs can operate normally, i.e. their function to make or break remains unaffected.
If an inner contact should weld, then the movement of the rotating armature is blocked via the actuator.
Open contacts of all four contact pairs remain open.
This arrangement corresponds to a conventional forcibly guided contact operation.
For Cautions for Use, see
4
Actuator
Actuator
Outer contact
Inner contact
Rotating armature
Outer contact
Inner contact
Rotating armature
Relay Technical Information.
ds_61407_en_sf4d: 011010D