HC4-HP-AC100V Panasonic Electric Works, HC4-HP-AC100V Datasheet - Page 8

no-image

HC4-HP-AC100V

Manufacturer Part Number
HC4-HP-AC100V
Description
RELAY PWR 4PDT 5A 100VAC PCB
Manufacturer
Panasonic Electric Works
Series
HCr
Datasheet

Specifications of HC4-HP-AC100V

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
13.2mA
Coil Voltage
100VAC
Turn On Voltage (max)
80 VAC
Turn Off Voltage (min)
30 VAC
Mounting Type
Through Hole
Termination Style
PC Pin
Circuit
4PDT (4 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
80 VAC
Control Off Voltage (min)
30 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-2772
HC4-HP-AC100V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HC4-HP-AC100V
Manufacturer:
PANASONIC/松下
Quantity:
20 000
Part Number:
HC4-HP-AC100V/110V
Manufacturer:
PANASONIC
Quantity:
12 000
HC
3. TM type
Chassis (Panel) cutout
Schematic
Same schematic as plug-in type HC relay
Be aware that there is no LED indicator with CR
circuit and built-in diode types.
For Cautions for Use, see Relay Technical Information.
2-3.6 dia.
2-.142 dia.
1.480
37.6
Tolerance: 0.1
.004
4 Form C type External dimensions
.142
3.6
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
13
1
5
9
13.35
.526
4.45
.175
20.6
.811
10
2
6
Chassis (Panel) cutout in tandem mounting
Notes: 1. In mounting, use M3 screws and M3 washers.
11
3
7
4
8
12
14
4.31
.170
.039
2.54
.100
4.06
.160
6.35
.250
6.35
.250
1
34.2
1.346
6.4
.252
2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover.
3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm).
27
1.063
Moreover, use washers to prevent loosening.
.020
0.5
37.6
1.480
1.480
37.6
General tolerance: 0.3
1.693
43
.827
.079
21
2
.906
23
.827
21
2
.079
.012
The diagrams show the external dimensions of
the 4 Form C and 4-pole bifurcated (twin) types.
For 1 Form C, 2 Form C, and 3 Form C, see
diagrams at plug-in types (only the terminals are
different).

Related parts for HC4-HP-AC100V