AHN22012 Panasonic Electric Works, AHN22012 Datasheet - Page 9

RELAY POWER SLIM 5A 12VDC

AHN22012

Manufacturer Part Number
AHN22012
Description
RELAY POWER SLIM 5A 12VDC
Manufacturer
Panasonic Electric Works
Series
AHNr
Datasheet

Specifications of AHN22012

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC
Coil Type
Standard
Coil Current
44.4mA
Coil Voltage
12VDC
Turn On Voltage (max)
8.4 VDC
Turn Off Voltage (min)
1.2 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
8.4 VDC
Control Off Voltage (min)
1.2 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
255-1509
6. About the relay-securing hook
• Screw terminal socket
1) Installation of the securing hook is
easily performed by pressing upward in
the direction of the arrows.
2) Removal of the securing hook is easily
performed by releasing the hook and
pressing down, as shown in the figure.
• Screw terminal socket
(Finger protect type)
1) Install the securing hook by pressing
the parts with arrows after inserting the
relay.
2) Removal of the relay is easily
performed by pressing the parts with
arrows.
For Cautions for Use, see Relay Technical Information.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
• PC board terminal socket
1) Installation of the securing hook is
easily performed by pressing upward in
the direction of the arrows.
2) Removal of the securing hook is easily
performed by releasing the hook and
pressing down, as shown in the figure.
* To prevent damage and deformity, please use
the relay-securing hook at 10 N or less.
7. Diode characteristics
1) Reverse breakdown voltage:
Min. 1,000V (with diode type)
Min. 400V (with diode and LED indication
type)
8. Diode type
Since the diode inside the relay coil are
designed to absorb the counter emf, the
element may be damaged if a large
surge, etc., is applied to the diode.
If there is the possibility of a large surge
voltage from the outside, please
implement measures to absorb it.
9. Installation
If you will be installing adjacent to other
relays, please keep a distance of at least
5 mm from the relay.
HN (AHN)