G2R-2-SND DC24(S) Omron, G2R-2-SND DC24(S) Datasheet - Page 10

RELAY PWR DPDT 5A 24VDC PLG

G2R-2-SND DC24(S)

Manufacturer Part Number
G2R-2-SND DC24(S)
Description
RELAY PWR DPDT 5A 24VDC PLG
Manufacturer
Omron
Series
G2RSr
Datasheets

Specifications of G2R-2-SND DC24(S)

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
380VAC, 125VDC - Max
Coil Type
Standard
Coil Current
21.6mA
Coil Voltage
24VDC
Turn On Voltage (max)
16.8 VDC
Turn Off Voltage (min)
3.6 VDC
Mounting Type
Socket
Termination Style
Socketable
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
5A @ 250VAC
Control On Voltage (max)
16.8 VDC
Control Off Voltage (min)
3.6 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G2R-2-SNDDC24(S)
G2R-2-SNDDC24(S)
G2R2SNDDC24S
Z2866
G2R
10
Ambient Temperature vs Maximum Coil Voltage
G2RK-1A, G2RK-1
Fully sealed Relays
G2R-14, G2R-1A4
5,000
1,000
1,000
5,000
500
100
100
50
500
50
Ambient temperature (°C)
30-VDC inductive load (L/R = 7ms)
AC coil
30-VDC
inductive load
(L/R = 7ms)
Switching current (A)
Switching current (A)
250-VAC/30-VDC
resistive load
DC coil
250-VAC/30-VDC
resistive load
250-VAC inductive
load (cosφ = 0.4)
250-VAC inductive
load (cosφ = 0.4)
Note: The maximum coil voltage refers to the maxi-
G2RK-2A, G2RK-2
G2R-24, G2R-2A4
10,000
5,000
1,000
5,000
1,000
500
100
500
100
mum value in a varying range of operating
power voltage, not a continuous voltage.
50
50
250-VAC inductive load (cosφ = 0.4)
Switching current (A)
Switching current (A)
250-VAC/30-VDC
resistive load
30-VDC inductive
load (L/R = 7 ms)
250-VAC inductive
load (cosφ = 0.4)
250-VAC/30-VDC
resistive load
30-VDC inductive load
(L/R = 7 ms)
G2R-1Z4, G2R-1AZ4
5,000
1,000
500
100
50
250-VAC inductive
load (cosφ = 0.4)
Switching current (A)
30-VDC inductive
load (L/R = 7 ms)
250-VAC/30-VDC
resistive load
G2R