n
n
n
n
n
Typical applications
Household appliances, boiler control, timers, garage door control, POS
automation
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Approvals
VDE REG.-Nr. C693, UL E214025
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Limiting making current (form A contact)
Breaking capacity max.
Contact material
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
Contact ratings
Type
IEC 61810
RZ03-1A.
RZ03-1C4
RZ01-1A3
RZ01-1A4
RZ01-1C4
RZ01-1.4
RZ0.-1A4
UL 508
RZ03-1A.
RZ03-1A4
RZ01-1A3
RZ03-1.4
RZ03-1.4
RZ03-1.4
RZ03-1A.
Mechanical endurance
1) planned rating
1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact
DC coil 400 mW
5kV/10mm coil-contact, reinforced insulation
Ambient temperature 85°C (clear cover: 70°C)
Product in accordance to IEC 60335-1
max. 4s, duty factor 10%
max. 20 ms (incandescent lamp); AgSnO
Contact
A (NO)
C (CO)
A (NO)
A (NO)
C (CO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
A (NO)
Load
16A, 250VAC, 85°C
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 70°C
10A, 250VAC, 85°C
16A, 250VAC, 85°C
12A, 250VAC, 85°C
12A, 250VAC, 85°C
B300, R300, 85°C
12A, 250VAC, 85°C
1/2hp, 125VAC, 85°C
1hp, 277VAC, 85°C
1 form C (CO) or 1 form A (NO)
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
3000VA
12A
12A
AgNi 90/10 or AgSnO
2
>10x10
360/72000h
250VAC
400VAC
8/6ms
4/6ms
General Purpose Relays
PCB Relays
Power PCB Relay RZ
6
30A
80A
operations
4000VA
-1
16A
16A
100x10
2
100x10
250x10
150x10
100x10
50x10
10x10
50x10
30x10
50x10
50x10
30x10
Cycles
6x10
6x10
3 1)
3
3
3
3
3
3
3
3
3
3
3
3
3
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Coil Data
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL1446
Coil versions, DC coil
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
Clearance/creepage
Material group of insulation parts
Tracking index of relay base
Coil
code
D003
D005
D006
D009
D012
D015
D024
D048
between open contacts
between contact and coil
between contact and coil
voltage
Rated
VDC
12
15
24
48
3
5
6
9
Operate
voltage
10.5
16.8
33.6
VDC
2.1
3.5
4.2
6.3
8.4
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
Release
voltage
V
VDC
0.3
0.5
0.6
0.9
1.2
1.5
2.4
4.8
Z
3 to 48VDC
≥10/10mm
1000V
5000V
PTI250V
class F
resistance
Ω±10%
IIIa
2
1440
5730
200
360
562
Coil
22
60
90
rms
rms
SCHRACK
Rated coil
F0305-A
power
mW
410
420
400
400
400
410
400
400
1