Specifications of G3TC-ODC5 DC5

Color
Red
Style
Standard
Voltage - Input
5VDC (2.5 ~ 8VDC)
Current - Input
18mA
Voltage - Output
5 ~ 60VDC
Current - Output
0.01 ~ 3A
Turn On Time
0.05ms
Turn Off Time
0.05ms
Features
Hold Down Screw
Control Voltage Type
DC
Input Voltage
2.5VDC To 8VDC
Contact Configuration
SPST-NO
Load Current
3A
Load Voltage Range
5VDC To 60VDC
Switching Mode
Zero Cross
Relay Terminals
Through Hole
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G3TC-ODC-DC5
G3TC-ODC5-DC5
G3TCODC5DC5
Z2031
■ Operating and Storage Environments
Operating Ambient Temperature
The rated value for the ambient operating temperature of the G3TC
is for when there is no built-up heat. For this, reason, under condi-
tions where heat dissipation is not good due to poor ventilation, and
where heat may build up easily, the actual temperature of the G3TC
may exceed the rated value resulting in malfunction or burning.
When using the G3TC, design the system to allow heat dissipation
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the
G3TC may increase as a result of environmental conditions (e.g., cli-
mate, air-conditioning) and operating conditions (e.g., mounting in an
airtight panel).
Operating and Storage Locations
Do not use or store the G3TC in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
1. Do not use or store in locations subject to direct sunlight.
2. Do not use in locations subject to ambient temperatures outside
3. Do not use in locations subject to relative humidity outside the
4. Do not store in locations subject to ambient temperatures outside
5. Do not use or store in locations subject to corrosive or flammable
6. Do not use or store in locations subject to dust (especially iron
7. Do not use or store in locations subject to shock or vibration.
8. Do not use or store in locations subject to exposure to water, oil,
Transportation
When transporting the G3TC, observe the following points. Not doing
so may result in damage, malfunction, or deterioration of perfor-
mance characteristics.
1. Do not drop the G3TC or subject it to severe vibrations or shock.
2. Do not transport the product if it is wet.
Vibration and Shock
Do not subject the SSR to excessive vibration or shock. Otherwise
the SSR may malfunction and internal components may be dam-
aged.
the range -30° to 80°C.
range 45% to 85% or locations subject to condensation as the
result of severe change in temperature.
the range -30° to 100°C.
gases.
dust) or salts.
or chemicals.