AQP811 Panasonic Electric Works, AQP811 Datasheet - Page 3

no-image

AQP811

Manufacturer Part Number
AQP811
Description
HEAT SINK STD FOR 10A & 15A
Manufacturer
Panasonic Electric Works
Series
AQ-Jr
Datasheet

Specifications of AQP811

Accessory Type
Heat Sink
For Use With/related Products
AQ-J Series
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
AQ-J
2) Output side
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
3. Characteristics (Measurement condition: at 20°C 68°F, input ripple: 1% or less)
REFERENCE DATA
(1) AQ-J Solid State Relays
1. Load current vs. ambient temperature Use load current within range specified in the figure below
Tested condition:
1) If attached to a heat sink, use a heat
conductive compound of similar coating to
improve cooling
2) Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
3) The current value is per 1a.
(2)-2. 15 A type (when using a heat sink)
Item
Output arrangement
Max. load current*
Load voltage
Frequency
Non-repetitive surge current*
“OFF-state” leakage current
“ON-state” voltage drop
Min. load current*
Operate time
Release time
Insulation resistance
Breakdown voltage
Vibration resistance
Shock resistance
Ambient temperature
Storage temperature
Operational method
(A) slim heat sink
(B) slim heat sink
(C) standard heat sink
(D) DIN rail mounting plate
(E) standard heat sink
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
20
15
10
5
0
When two units are mounted
on an (B) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
0
When two units are mounted
on an (A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is mounted
on an (B) slim heat sink
20
3
1
Ambient temperature, °C
Item
40
2
AQP-HS-SJ20A
AQP-HS-SJ10A
AQP-HS-J10A
AQP-DPJ
AQP-HS-J25A
60
When a single unit
is mounted on an
(A) slim heat sink
80
Part No.
100
Max. 1/2 cycle of voltage sine wave + 1ms
Max. 1/2 cycle of voltage sine wave + 1ms
Min. 100MΩ between input, output and case
3,000 Vrms between input and output
2,500 Vrms between input, output and case
SSR stand-alone: 10 to 55Hz, double amplitude of 1.5mm
Slim heat sink combined type: 10 to 55Hz, double amplitude of 0.75mm
SSR stand-alone: Min. 980m/s
Slim heat sink combined type: Min. 197m/s
–30 to +80°C
–30 to +100°C
Zero-cross (Turn ON and Turn OFF)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
(1) 10 A type (when using heat sink or iron
plate)
(3)-1. 25 A type (when using iron plate)
AQJ112VY
AQJ119VY
AQJ116VY
100A
10A
–22 to +176°F
–22 to +212°F
12
10
30
25
20
15
10
8
6
4
2
0
5
0
-20
0
When two units are mounted
on an (A) slim heat sink
When using 300 × 300 × t2 mm iron plate
When a single unit is mounted on an (A) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
When a single unit is mounted
on an (C) standard heat sink
When two units are mounted
on an (B) slim heat sink
When using 100×100×t1.6 mm iron plate
When using 150 × 150 × t1.6 mm
iron plate
When a single unit is mounted
on an (B) slim heat sink
0
20
When using 250 × 250 × t2 mm
iron plate
1a
When using 100 × 100 × t1.6 mm
iron plate
Ambient temperature, °C
Characteristics
2
Ambient temperature, °C
20
40
40
AQJ412VY
AQJ419VY
AQJ416VY
60
250A
When using
200 × 200 × t2 mm
iron plate
20A
2
60
80
80
75 to 264V AC
45Hz to 65Hz
Max. 5mA
Max. 1.6V
100
50mA
(2)-1. 15 A type (when using iron plate)
(3)-2. 25 A type (when using a heat sink)
AQJ112VW
AQJ119VW
AQJ116VW
100A
10A
30
25
20
15
10
18
15
12
5
0
9
6
3
0
-20
at 500 V DC
for 1min.
X, Y, Z axes
X, Y, Z axes
Non-condensing at low temperatures
0
When using 200 × 200 × t2 mm iron plate
When using
100 × 100 × t1.6 mm
iron plate
When a single unit is
mounted on an (E)
standard heat sink
When a single
unit is mounted on an
(B) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
When two units are
mounted on an (A)
slim heat sink
0
20
1a × 2
Ambient temperature, °C
When using
150 × 150 × t1.6 mm
iron plate
Ambient temperature, °C
20
40
When two units
are mounted on an
(B) slim heat sink
Remarks
When a single unit is mounted
on an (C) standard heat sink
40
60
AQJ412VW
AQJ419VW
AQJ416VW
When a single unit is
mounted on an (A)
slim heat sink
250A
15A
60
80
80
100

Related parts for AQP811