Y92H-7 Omron, Y92H-7 Datasheet - Page 15

no-image

Y92H-7

Manufacturer Part Number
Y92H-7
Description
CLIP HOLD DOWN FOR PL08/11 SOCKT
Manufacturer
Omron
Datasheets

Specifications of Y92H-7

Accessory Type
Clip, Hold Down
For Use With/related Products
PL08 and PL11 Sockets
For Use With
Z838 - RELAY SOCKET 3PDT PANEL MT MKZ836 - RELAY SOCKET DPDT PANEL MT MK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92H7
H3CR-A8E
Note: 1. The minimum power-opening time (“Rt”) is 0.1 s.
Nomenclature
Time range selector (select one
from 1.2, 3, 12, and 30 at full
scale; with the H3CR-A@-301,
select from 2.4, 6, 24, or 60 at
full scale.)
A:
ON-delay
B
Flicker ON
start
E:
Interval
J:
One-shot
output
Operating
2
:
mode
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
Output indicator (orange)
(Lit when output)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NC)
Instantaneous
output relay (NO)
Output relay (NC)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NO)
Output relay (NO)
(output indicator)
Instantaneous
output relay (NC)
Instantaneous
output relay (NO)
Instantaneous
output relay (NC)
Power indicator
Instantaneous
output relay (NC)
Output relay (NC)
Instantaneous
output relay (NO)
Output relay (NC)
Output relay (NO)
(output indicator)
Output relay (NC)
Power indicator
Power indicator
Power indicator
Power
Power
Power
Power
Power indicator (green) (Flashes when Timer
operates; lit when Timer stops operating)
(Fixed)
Time setting
knob (set time)
Timing chart
Operating mode display window
Operating mode selector
Select a mode from:
A, B, B2, C, D, and E (H3CR-A, -AP, and -AS) A,
Scale range display windows
Time unit display window
Time unit selector (select one
from sec, min, hrs, and 10h)
(Fixed)
B2, E and J (H3CR-A8, -A8S, and -A8E) G
and J (H3CR-A-300)
Power
Output
Basic operation
Power
Output
Power
Output
Basic operation
Basic operation
Power
Output
Basic operation
t
t
t
t
t
t
H3CR-A
1±0.6 s
(Fixed)
t
15