37D645 Tyco Electronics, 37D645 Datasheet

MOUNTING STRIP SOCKET DP-8P

37D645

Manufacturer Part Number
37D645
Description
MOUNTING STRIP SOCKET DP-8P
Manufacturer
Tyco Electronics
Series
R10r
Datasheets

Specifications of 37D645

Accessory Type
Mounting Strip
For Use With/related Products
R10 Series
For Use With
27E164 - SOCKET PHEN 6POLE FOR R10 SERPB802 - SOCKET 4POLE R10 SERIESPB801 - SOCKET DP-2P R10 SERIESPB798 - SOCKET 6P SOLDER R10 SERIESPB133 - R10 RELAY SOCKETS-TERMINALSPB132 - R10 RELAY SOCKETS-TERMINALS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
37D645
7-1393143-3
PB816

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
37D645
Manufacturer:
TE Connectivity
Quantity:
1 847
Dimensions are shown for
reference purposes only.
Features
• Broad range of coil options provide sensitivity ranging from 25 to 750mW.
• Various contacts switch from dry circuit to 7.5 amps.
• Many mounting and termination options.
Contact Data @ 25°C
Arrangements: 1 Form C (SPDT) through 8 Form C (8PDT) See Ordering
Information tables for more details regarding availability.
Contact Materials, Styles & Ratings @ +25
‡ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 7.5A at 115VAC and
§ Use ungrounded frame for AC loads of 5A or greater. Max.ratings are 5A at 115VAC and 3A
UL Horsepower Contact Ratings (Coil Code V Only)
Expected Mechanical Life: 100 million operations, typical. (Except contact
Typical Expected Life For Resistive Loads @ 25
†† Relay operated at rated coil voltage or 133% of pick-up current or higher.
Initial Dielectric Strength
Between Open Contacts: 500V rms, for contact codes P and Z.
Between All Other Conductors: 1,000V rms.
Contact
Type
R10S
R10S
R10S
R10S
Code
4A at 28VDC for coil codes S and J.
at 28VDC for coil codes S and J.
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
R10
Ratings are at 28VDC or 155VAC unless otherwise specified. Total load must not
exceed 30A per relay.
W
Contact Code
X
Y
Z
P
W
Current
Silver-Cadmium Oxide
Silver-Cadmium Oxide
X
500mA
100mA
100mA
100mA
100mA
Gold overlay on Silver Bifurcated Crossbar
30mA
50mA
7.5A
5.0A
2.0A
2.0A
2.0A
1.0A
1.0A
1.0A
1mA
7.5A
5.0A
4.0A
3.0A
3.0A
R10
Material
Fine Silver
Contact
Fine Silver
28VDC or 120VAC
28VDC or 120VAC
28VDC or 120VAC
No. of Poles
120VAC, 60 Hz.
120VAC, 60 Hz.
1, 2, 4, 6
1, 2, 4
Voltage
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
28VDC
48VDC
6VDC
6VDC
6VDC
6VDC
1,000V rms for contact codes W, X and Y with
coil code V.
Code W: 1,000,000 operations, typical.)
Single Button
Single Button
Single Button
Bifurcated
Contact
Style
R10-R
At 110-120VAC
1/20 HP (1.5A)
Contact Style Coil Code Operations††
1/8 HP (3.8A)
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Y,Z
P,Z
P,Z
P,Z
Dimensions are in inches over
(millimeters) unless otherwise
specified.
W
W
W
X
X
X
P
P
P
Coil Codes
Available
V, Q, S, J
V, Q, S, J
All
All
All
°
C
°
SS,JJ
SS,JJ
SS,JJ
SS,JJ
SS,JJ
V,S,J
V,S,J
V,S,J
V,S,J
V,S,J
V,S,J
Dry Circuit 1mA
C
S,J
S,J
S,J
R10S
500mA
V
V
V
J
J
500mA
100mA
J
J
1mA
Min.
Contact Ratings
At 220-240VAC
1/10 HP (1.5A)
1/6 HP (2.2A)
100mA
Typ.
7.5 · 10
7.5 · 10
1.5 · 10
2A
12 · 10
5 · 10
5 · 10
2 · 10
2 · 10
3 · 10
6 · 10
5 · 10
5 · 10
1 · 10
5 · 10
1 · 10
5 · 10
5 · 10
1 · 10
5 · 10
5 · 10
5 · 10
-
-
Catalog 1308242
7.5A‡
4
4
4
4
4
5
5
5
6
6
8
6
7
6
7
6
7
Max.
6
5A§
4
4
6
3A
2A
3A
Issued 3-03
R10
General Purpose
Dry Circuit to 7.5 Amp
Multicontact AC or DC Relay
• R10-E – Clear Dust Cover Version
• R10-R – Sealed, Immersion Cleanable Type
• R10S – Super Sensitive, Logic Compatible
Capacitance
Between Contacts: 2 pf, typ.
Between Contacts and Coil: 2 pf, typ.
Between Coil and Frame: 30 pf, typ.
Initial Insulation Resistance
Between Mutually Insulated Elements: 10
Consult factory for optional acetal resin material rated 10
Coil Data @ 25°C (also see Coil Data tables)
Voltage: 3 to 115VDC and 6 to 115VAC.
Maximum Coil Power: 2.2 Watts.
Coil Temperature Rise: 30°C per Watt.
Maximum Coil Temperature: 105°C.
Operate Data @ 25°C
R10 Ultra-Sensitive "SS" and "JJ" Typical Ranges of Operation
Environmental Data
Storage Temperature Range: -55°C to +105°C.
Operating Temperature Range: -55°C to +75°C.
Mechanical Data
Terminal Finish: Tin plating standard.
Weight: 0.8 to 1.4 oz. (23 to 40g) approximately.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
R10 Relays (DC Only) Typical Ranges of Operations
20
25
15
10
30
Multiple of Max. Pull-In Voltage or Current
40
5
values are required, testing is required.)
50
30
20
10
1.0
(Curves for reference only. If specific
1.0
File E29244
File LR15734
Specifications and availability
subject to change.
values are required, testing is required.)
1.5
series
Multiple of Max. Pull-In Voltage or Current
(Curves for reference only. If specific
1.33 1.5
(all contact configurations)
2.0
(all contact configurations)
and Release Times
Typical Operate
Operate Time
and Release Time
Typical Operate
(no suppression)
Release Time
Operate Time
3.0
2.0
(no suppression)
Release Time
4.0
10
8
6
4
2
2.5
10
ohms @ 25°C, 50% RH.
3.0
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
12
10
12
8
6
4
2
ohms.
P&B
703

Related parts for 37D645

37D645 Summary of contents

Page 1

... Typ. Max. Maximum Coil Temperature: 105°C. 500mA - 7.5A‡ 500mA - 5A§ Operate Data @ 25°C 100mA 2A 3A R10 Relays (DC Only) Typical Ranges of Operations 1mA 100mA 2A Dry Circuit 1mA 3A (Curves for reference only. If specific values are required, testing is required 220-240VAC 1/6 HP (2.2A ...

Page 2

... Standard AC Operated Relays Coil Resistance ° ± C 20% (ohms) Volts Pick-Up 6 & 8 Form C (max.) Nominal 25 15 5.0 120 90 9.0 500 350 18.0 2 ...

Page 3

Ordering Information Typical Part Number 1. Basic Series: R10 = Relay with Form C contacts. R10S = Super sensitive R10 (case and terminals E1 & E2 only, J coil adj. only). 2. Case Style Non-sealed polycarbonate cover. R ...

Page 4

Outline Dimensions .735 MAX. (18.67) CASE E ONLY .406 (10.31) .085 MAX. (2.16) .135 (3.43) .171 .354 (4.43) (8.99) .210 (5.33) 3-48 THREAD } TYPE E1 ONLY NIB .091 DIA. x .020 HIGH (2.31) (.51) .59 REF . (15.0) Solder ...

Page 5

... Hold Down Spring See following page for additional sockets & accessories. 37D645 – Mounting Strip Strip of .060” (1.52mm) aluminum contains ten pre-punched, breakaway mounting plates. Each plate accomodates pole solder terminal R10 relay or socket to facilitate chassis- or rack mounting. ...

Page 6

... Requires only one chassis cutout. Track Mount Socket Provides front wiring, screw terminal connections for R10 family relays. No grounding provision. See preceding page for hold down springs. Suggested Track Mounting 27EXXX .187 MIN. ...

Related keywords