TOOLSTICK912UPP Silicon Laboratories Inc, TOOLSTICK912UPP Datasheet - Page 11

ADAPTER PROGRAM TOOLSTICK F91X

TOOLSTICK912UPP

Manufacturer Part Number
TOOLSTICK912UPP
Description
ADAPTER PROGRAM TOOLSTICK F91X
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
Microcontroller Programmerr
Datasheets

Specifications of TOOLSTICK912UPP

Contents
Base Adapter, C8051F330 Daughter Card and USB Cable
Processor To Be Evaluated
C8051F912
Processor Series
C8051F9xx
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F91x/0x QSOP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1867
7.2. Connecting to the Device and Downloading Firmware
This section describes how to open the IDE, open and build a project, connect to a device and download the
firmware.
1. Open the Silicon Laboratories IDE from the Start  Programs  Silicon Laboratories menu.
2. In the IDE, go to Project  Open Project.
3. Browse to the default installation location C:\SiLabs\MCU\ToolStick\F912DC\Firmware\.
4. Select F912DC_FeaturesDemo.wsp and click OK.
5. In the IDE, select Project  Rebuild Project.
6. Go to Options  Connection Options.
7. Select “USB Debug Adapter” for the Serial Adapter and “C2” for the Debug Interface, and then click “OK”.
8. Go to Debug  Connect.
9. Download the code using the download button on the menu bar or use alt-D.
Once these steps are completed, the firmware is built into an object file (step 5) and downloaded to the device
(step 9). The device is now ready to begin executing code. If all of these steps were followed successfully, the “Go”
option is enabled in the Debug menu. A green circle icon in the IDE toolbar also indicates that the device is ready
to run. If one of the steps leads to an error, make sure that the ToolStick is properly inserted in a USB port and start
again with step 6.
7.3. Running and Stopping Code Execution
Once the IDE is connected to the device and the firmware is loaded, the IDE can start and stop the code execution.
The following steps can be performed using the buttons on the toolbar or using the options in the Debug menu.
1. To start code execution, click the green “Go” button on the toolbar or use the Debug  Go menu option. The
2. To stop code execution, click the red “Stop” button on the toolbar or use the Debug  Stop menu option. The
All debug windows and watch windows are refreshed when the device is stopped. If any of the values in these
windows have changed since the last time the device was halted, the new value is shown in red text instead of
black text.
green LED on the daughter card will start to flash. The debug commands in the IDE (single-step, multiple-step,
set breakpoint, and others) are disabled when the device is running. While the firmware is running, the
potentiometer on the daughter card can be turned to alter the blinking speed of the LED. The button labeled P2.4
can also be pressed to toggle the ADC on and off. When the ADC is off, the blink rate or brightness of the LED will
not change.
device will halt code execution and all of the registers and pins on the device will hold their state.
Rev. 0.1
ToolStick-F912DC
11