XE8000MP Semtech, XE8000MP Datasheet - Page 29

PROG BOARD AND PROSTART2 CARD

XE8000MP

Manufacturer Part Number
XE8000MP
Description
PROG BOARD AND PROSTART2 CARD
Manufacturer
Semtech
Type
Microcontroller Programmerr
Datasheets

Specifications of XE8000MP

Contents
Multipurpose Board, Programming Algorithm, Power Supply and Level Shifters
For Use With/related Products
XE8000 Series
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
8.4
Table 8 : Default jumpers settings
8.5
The evaluation board can be powered with a 2.4 to 5 V lithium battery.
The battery needs to be inserted in the correct way.
When connected to the motherboard the evaluation board is automatically powered by the motherboard, the battery or
external power supplies are bypassed.
The on-off button allows the user to the switch between the battery supply and the external source supply.
When the on-off button is set to external source supply, the battery is not subject to discharge.
8.6
To operate the microcontroller with an external oscillator connected to the OSCin pin, first remove the “external clock
source” jumper on the socket board. Once completed, connect the external oscillator to the header on pin “OSCIN”.
8.7
This enables users to restart the program.
When the power supply is turned off and on, the power on reset feature can be disturbed by the time of the Vreg
capacitor discharge (Vreg capacitor = 1uF).
To ensure a better start-up of the chip, it is advised to use the reset button in order to ensure the reset functionality.
© Semtech 2006
Jumper name
version
dependent
version
dependent
br_consumption
near the xtal
near the
EEPROM
EEPROM
supply
JUMPER DEFAULT SETTINGS
EXTERNAL POWER SUPPLY
EXTERNAL CLOCK ON OSCIN
RESET BUTTON
On all the future versions of daughter boards there will be different jumper configurations. However there are
some common jumpers that will be described in the table below.
*Note that when you’re using the EEPROM, you must disable the PB4 and PB5 LED’s.
When you’re using a battery supply, it’s suggested to disable the LEDs.
Function
LEDs on I/O ports
Buttons on input port
Used to put an ampere meter in
serial with uC VBAT
source on xin and xout
connects PB4 & PB5 to the
EEPROM
Disconnects VBAT for the
EEPROM
Allows the user to put another xtal
Open
LEDs disabled
Buttons disabled
No uC VBAT
(measurement)
User Xtal
Disconnected
Disconnected
29
Closed
LEDs enabled
Buttons enabled
VBAT connected to uC
Board Xtal
Connected
Connected
XE8000 ProStart II
User Guide
Default
Closed
Closed
Closed
Closed
Closed *
Closed
www.semtech.com