SUPERPRO 5000 Xeltek, SUPERPRO 5000 Datasheet - Page 70

PROGRAMMER UNIV STANDALONE W/USB

SUPERPRO 5000

Manufacturer Part Number
SUPERPRO 5000
Description
PROGRAMMER UNIV STANDALONE W/USB
Manufacturer
Xeltek
Series
SuperPro 5000r
Type
Universal, Stand Aloner
Datasheet

Specifications of SUPERPRO 5000

Contents
Programmer, Power Supply Adapter, Software, Cables and Documentation
Ic Product Type
Programmer, Universal
Ic Interface Type
USB
No. Of Devices Supported
41848
Kit Contents
Programmer W/ A DIP48 Adapter, AC Adapter, Software CD, USB2.0 Cable, And User's Manual
Rohs Compliant
Yes
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet. 44,000+ Devices Supported.
For Use With
415-1037 - SOCKET ADAPTER 32PLCC SUPERPRO5K415-1045 - SOCKET ADAPTER 84PLCC SUPERPRO5K415-1044 - SOCKET ADAPTER 28SOIC SUPERPRO5K415-1043 - SOCKET ADAPTER 28SSOP SUPERPRO5K415-1042 - SOCKET ADAPTER 56TSOP SUPERPRO5K415-1041 - SOCKET ADAPTER 40TSOP SUPERPRO5K415-1040 - SOCKET ADAPTER 16SOP SUPERPRO5K415-1039 - SOCKET ADAPTER 48TSOP SUPERPRO5K415-1038 - SOCKET ADAPTER 44PLCC SUPERPRO5K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1036
Select Auto to finish all the operations in one step.
Execute Production Mode to Program Chips in Batches
Select Production Mode from the Option menu to program devices in large
quantities. This function facilitates the job of the user who programs chips in
batches.
In order to program chips in batches, the programmer always conducts the
insertion test.
The programmer waits for the chip insertion. The system displays the following
prompt: Please, insert a device into the socket. Refer to Insertion Test on page
82 for detailed information on chip insertion error messages.
Once you have properly inserted the chip, the auto batch‐processing
command starts automatically.
The programmer waits for the chip removal. When chip programming is complete,
the system displays the following prompt: Please, remove the device from the
socket.
Review the Operation Information window to check the programming result.
Refer to Operation Information Window on page 59 for more information.
To end production mode, select Cancel on the right side of the status bar.
Security and Password Input
To prevent the user’s data from being used by another, the program asks the user
to input the password in the operation process.
The Set Password screen is illustrated below.
Superpro
Verify
Security or Protect if encryption is required
Note: This step is necessary. The chip must pass Verification before the
Note: You may need to set the configuration word before performing
®
programming can be implemented. Some chips provide only the
accumulation check function, such as VerifyCRC instead of a
unit‐to‐unit check function. Very few chips do not provide the
accumulation check function.
encryption. Refer to Device Configuration Word on page 37 for more
information.