HS7751RKCM01H Renesas Electronics America, HS7751RKCM01H Datasheet - Page 241

no-image

HS7751RKCM01H

Manufacturer Part Number
HS7751RKCM01H
Description
ON CHIP DEBUG EMULATOR W/TRACE
Manufacturer
Renesas Electronics America
Datasheets

Specifications of HS7751RKCM01H

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
6.5.6
1. Errors
2. Functions that cannot be used while the profile function is being used
10. When continuous trace is used, do not enable user interrupt by the INTERRUPT
The profile function internally breaks user program execution, collects the measured data, and
re-executes the user program.
Since the function also counts when the measured item is generated at break or re-execution,
an error will be included in the measured profile value.
The measured value of this function should be the target.
(a) Performance measurement function
(b) Step function
(c) Memory access during user program execution
(d) Continuous trace function
(e) Internal trace function
(f) Halt function
command during the emulator command wait state or user program execution.
The profile function is implemented by using the performance measurement function
described in section 6.5.7 (1), Performance measurement function. This function cannot
be used when the profile function is enabled.
When the profile function is enabled, do not use the step function. The profile data cannot
be measured correctly.
When the profile function is enabled, memory access is disabled during user program
execution.
When the profile function is enabled, do not use the continuous trace function that can be
used in the internal trace function. The profile data cannot be measured correctly.
When the profile function is enabled, mode selection of the internal trace is disabled since
all items of the internal trace modes are selected in the emulator.
When the profile function is enabled, do not use the halt function for the internal or AUD
trace.
9. When the [Acquire continuous trace] check box is selected, and when either the
Notes on Using the Profile Function
An internal I/O trace cannot be made with the Step In function.
The LDTLB instruction and internal I/O trace cannot be performed with the Step
Over function.
[Get trace information of internal I/O area] radio button (internal I/O trace
enabled) or the [Get trace information of LDTLB instruction] radio button is
selected (LDTLB instruction trace enabled) with the [Break Condition 5] dialog
box,
213

Related parts for HS7751RKCM01H