ZGP323ICE01ZEM Zilog, ZGP323ICE01ZEM Datasheet - Page 16

no-image

ZGP323ICE01ZEM

Manufacturer Part Number
ZGP323ICE01ZEM
Description
PLATFORM DEV ICE Z8 GP ZGP323
Manufacturer
Zilog
Datasheet

Specifications of ZGP323ICE01ZEM

Processor To Be Evaluated
ZGP323
Interface Type
RS-232, Ethernet, USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3399
ZGR323ICE01ZEM
Sample Project
UM017503-0208
Note:
If you run the emulator with a target attached, the emulator’s voltage comparator is
designed to serve as a target power sensor, and not as a precision voltage measurement
device. If you set the Target VCC to match your target and the target’s voltage drifts down-
ward, the power sensor may no longer detect it. The emulator may therefore not connect to
the target. In such cases, set the Target VCC voltage progressively lower until a proper
connection is established.
After installing the ZDS II software and setting up the hardware, you can execute the sam-
ple software project to verify proper emulator operation and to test with the Trace and
Event system. This section describes how to run the emulator in the in-circuit mode.
The sample project
in:
c:\Program Files\ZiLOG\ZDSII_<product>_<version>\sam-
ples\<processor type>_<demo name>
Start ZDS II for the Z8 GP ICE Emulator by selecting Start
Emulator Kit_
the sample project.
1. Use File
2. To open the source file, double-click main.c in the Project Files Window.
3. Select Project
4. In the General tab, set the CPU Family field to ZGP323 and the CPU field type to
5. In the Debugger tab select Ethernet Driver from the from the Driver drop-down
6. The Ethernet Configure Driver dialog appears. The IP Address field displays a
7. Click OK.
8. In the Debugger tab, set the Target drop-down menu to ZGP323ICEXXZEM and
9. Set the Voltage drop-down menu to 3.0 V. If the emulator is connected to a custom
following path:
c:\Program Files\ZiLOG\ZDSII_Z8GP_Emulator_ <version>\sam-
ples\ZGP323_ledBlink\ledblink_c\src\ ledblink_c.pro
ZGP323XXX2832.
menu and click Configure button.
default IP address, 192.168.1.50. Enter the Z8 GP ICE IP address if it has been modi-
fied. Leave the Port setting at 4040.
click Configure button. The Configure Target window appears.
target, select the voltage appropriate for the connected target.
Z8 GP
<revision>
Open Project menu option to open the sample project file located at the
ledblink_c.pro
Settings.
ZGP323 In-Circuit Emulator and Development Platform
and follow the instructions below to run
is included in the ZDS II sample directory, located
ZiLOG ZDS II-Z8 GP
ledblink_c.pro
Sample Project
User Manual
,
13

Related parts for ZGP323ICE01ZEM