AD9956-VCO/PCB Analog Devices Inc, AD9956-VCO/PCB Datasheet - Page 8

no-image

AD9956-VCO/PCB

Manufacturer Part Number
AD9956-VCO/PCB
Description
BOARD EVAL 14BIT 1.8V 48LFCSP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of AD9956-VCO/PCB

Module/board Type
Evaluation Board
For Use With/related Products
AD9956
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
AD9956/PCB
DUT SIGNALS DIALOG BOX
This dialog box controls the reset, I/O update, and I/O reset
signals for the master and slave devices. Click the lock icon
between the corresponding Master and Slave buttons to lock the
two together. Click Master or Slave Reset, I/O Update, or I/O
Reset, to specify the unit that issues the command to both
devices.
The auto I/O update function is controlled in the Enable Auto
I/O Update section. Select either Master–Auto I/O Update,
Slave–Auto I/O Update, or both to send an I/O update to the
device(s) every time you click LOAD (default on). If you want a
device to wait for a manually sent I/O update signal, clear the
corresponding check box.
Figure 7. DUT Signals Dialog Box
Rev. 0 | Page 8 of 12
DUT I/O DIALOG BOX
This dialog box controls the I/O configuration for the device.
Click I/O Reset Master or I/O Reset Slave to send an I/O reset
to the corresponding serial port state machine.
Select LSB First to change the data format to LSB first. The
default is MSB first.
In the Serial I/O Mode section, select either 2 Wire or 3 Wire
from the drop-down list to specify the part as either, respectively,
a 2-wire serial port, in which the serial data line is I/O, or a
3-wire serial port, in which the serial data is input on SDI/O
and read back on SDO.
Figure 8. DUT I/O Dialog Box

Related parts for AD9956-VCO/PCB