SUPERPRO3000UCLUSTER(ROHS) Xeltek, SUPERPRO3000UCLUSTER(ROHS) Datasheet - Page 37

no-image

SUPERPRO3000UCLUSTER(ROHS)

Manufacturer Part Number
SUPERPRO3000UCLUSTER(ROHS)
Description
PROGRAMMER QUAD STANDALONE W/USB
Manufacturer
Xeltek
Series
SuperPro 3000U-Clusterr
Type
Gang-Universal Programmerr

Specifications of SUPERPRO3000UCLUSTER(ROHS)

Contents
4 Ganged SuperPro 3000U Units, AC Adapter, CD, USB Cable, Users Guide and Power Supply
For Use With/related Products
E/EPROM, FLASH, PLD, Micros and more listed on Device Sheet. 44,000+ Devices Supported.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
415-1008
SUPERPRO 3000U CLUSTER
SUPERPRO 3000U CLUSTER(ROHS)
The last 4 bytes of buffer data is:
FFC: 30 FFD: 30 FFE: 30 FFF: 31
If programming succeeds Operation Info screen displays:
Current AutoIncrement Data = 0002
The last 4 bytes of buffer data is:
FFC: 30 FFD: 30 FFE: 30 FFF: 32
Device
This selection allows users to program only utilize part of the chip, applicable to most E/EPROM (Flash)
device.
For example, MACRONIX MX29F200B TSOP48 is a 16 bit Flash device. Its program zone start and
end address is 0 and 1FFFF (Hex), and data buffer capacity is (1FFFF+1)*2=40000 (Hex,). Since it’s a
16-bit device, data buffer capacity is 2 times of that of the device. The default method is programming
from the start address to the end address. If user only wants to program the chip’s last part, please set the
start address to 10000 (Hex), and remain the end address default value. Thus the data for programming
are the data in data buffer between 20000 (Hex) and 40000 (Hex).
This function not only makes programming more flexible but also saves time under the Production
Mode.
Verify Mode
It is necessary to verify after the programming of a chip. According to the reference to the manufacture,
the requests of VCC voltage for verification are different.
1. Use VCC (+/- 5%) or (+/- 10%) to verify. For example, VCC=5.00V. Use VCC=5.00V to verify once,
or use VCC=4.74V and VCC =5.25V to verify twice (+/- 5%), or use VCC=4.50V and VCC=5.50V to
verify twice (+/- 10%).
2. Use MinVcc and MaxVcc to verify.
Note: The Operation Option will vary with the various devices. i.e. Most SCMs don’t allow user to set
the start and end address of the device.
4.1.4.2 Edit Auto
In the Edit Auto dialogue box, all devices have an Auto option, which is like a batch command. This
function allows the software auto operate in order displayed in the right column. For example, select