E240 Atmel, E240 Datasheet - Page 6

no-image

E240

Manufacturer Part Number
E240
Description
BOARD EVAL FOR QT240-IS QTOUCH
Manufacturer
Atmel
Series
Quantumr
Datasheet

Specifications of E240

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
427-1082

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E2405D-1W
Manufacturer:
MORNSUN/金升阳
Quantity:
20 000
Part Number:
E2405D-2W
Manufacturer:
MORNSUN/金升阳
Quantity:
20 000
Part Number:
E2405D-2WR2
Manufacturer:
MONRSUN
Quantity:
20 000
Part Number:
E2405S-1W
Manufacturer:
ARCH
Quantity:
12 000
Part Number:
E2405S-1W
Manufacturer:
MORNSUN/金升阳
Quantity:
20 000
Part Number:
E2405S-1WR2
Manufacturer:
MORNSUN/金升阳
Quantity:
20 000
Part Number:
E2405S-2W
Manufacturer:
MORNSUN
Quantity:
12 000
Part Number:
E2409S-1W
Manufacturer:
MORNSUN
Quantity:
12 000
Part Number:
E2409S-2W
Manufacturer:
MORNSUN
Quantity:
12 000
Part Number:
E240B
Manufacturer:
Atmel
Quantity:
135
4
The E240 is a simple double-sided PCB on industry standard FR4 material. All parts are
standard surface mount types. Here is a brief description of some of the parts and features.
Keys — Keys consists of capacitive electrodes formed using copper areas on the E240 which
project a capacitive field through the overlying dielectric panel material.
Electrodes — Copper areas on the PCB which define the touch keys.
LEDs — The board has one ‘Power’ LED which remains on as long as the board is powered,
plus one LED per key to indicate touch.
Connector CN1 — The main interface connector is located at one end of the E240 board. The
pinout of this connector is shown in Table 1 (next page). The pin functions are as follows:
[1] SYNC — Not used in fast mode (the default setting). SYNC is available in slow mode
[2..5] OUT ‘A’ ~ OUT ’D’ — OUT pins are low when the corresponding key is inactive and
[6] /RESET — Can be left floating, as the board has its own internal reset circuit. To reset
[7, 8] +POWER, GND — Use +7 to +12VDC connected between the +POWER and GND to
only and is used to synchronize the E240 burst with an external falling edge signal,
usually derived from a 50 or 60Hz source to suppress mains interference, or to allow
two or more QT240 chips to synchronize to to each other, to prevent cross-interference
effects between the adjacent keys of different chips.
high when active, and are controlled by the QT240 chip. These lines also control the
LEDs.
the E240 externally (for example to force all keys to recalibrate), connect RESET to
GND for at least 1ms, then release it; the board will restart, recalibrate and be ready to
detect touches again after about 180ms.
power the E240 board. The battery snap feeds the same two connections, and can also
be used for power input.