IE-789234-NS-EM1 Renesas Electronics America, IE-789234-NS-EM1 Datasheet

no-image

IE-789234-NS-EM1

Manufacturer Part Number
IE-789234-NS-EM1
Description
BD EMULATOR 78K0S KX1 UPD789234
Manufacturer
Renesas Electronics America
Datasheet

Specifications of IE-789234-NS-EM1

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website: http://www.renesas.com
Old Company Name in Catalogs and Other Documents
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for IE-789234-NS-EM1

IE-789234-NS-EM1 Summary of contents

Page 1

... NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document valid Renesas Electronics document. We appreciate your understanding. Renesas Electronics website: http://www.renesas.com Issued by: Renesas Electronics Corporation (http://www ...

Page 2

... Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific” or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics. The quality grade of each Renesas Electronics product is “ ...

Page 3

... User’s Manual IE-789234-NS-EM1 Emulation Board Target Devices 78K0S/KU1+ 78K0S/KY1+ 78K0S/KA1+ 78K0S/KB1+ Document No. U17381EJ6V0UM00 (6th edition) Date Published June 2007 NS 2005 Printed in Japan ...

Page 4

User s Manual U17381EJ6V0UM ...

Page 5

... Please check with an NEC Electronics sales representative for availability and additional information. • No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Electronics. NEC Electronics assumes no responsibility for any errors that may appear in this document. ...

Page 6

... If the cable of the power supply, the PC interface cable, the emulation probe, or the like was bent or pulled excessively • power supply unit other than the supplied product was used • If the product got wet • If this product is connected to the target system when there is a potential difference between the GND of this product and GND of the target system. • ...

Page 7

... Cautions 1. The IE-789234-NS-EM1 has usage restrictions. Target Readers This manual is intended for engineers who will use the IE-789234-NS-EM1 with the IE- 78K0S-NS or IE-78K0S-NS-A to perform system debugging. Engineers who use this manual are expected to be thoroughly familiar with the target device’s functions and use methods and to be knowledgeable about debugging. ...

Page 8

... It is assumed that the readers of this manual have general knowledge in the fields of electrical engineering, logic circuits, and microcontrollers. To understand the overall functions and usages of the IE-789234-NS-EM1 → Read this manual in the order of the CONTENTS. The mark “<R>” shows major revised points. The revised points can be easily searched by copying an “ ...

Page 9

... Initial Settings of Switches and Jumper .................................................................................................. 15 2.3 Other Initial Settings .................................................................................................................................. 15 CHAPTER 3 INSTALLATION .................................................................................................................16 3.1 Connection ................................................................................................................................................. 17 3.1.1 Connection with IE-78K0S-NS or IE-78K0S-NS-A main unit ......................................................... 17 3.1.2 Setup of probe interface conversion board .................................................................................... 17 3.1.3 Connection with target system ....................................................................................................... 17 3.2 Switch and Jumper Settings on Main Unit............................................................................................... 22 3.3 Setting Power Supply Voltage of Target Interface .................................................................................. 23 3 ...

Page 10

... The IE-789234-NS-EM1 is a development tool for efficient debugging of hardware or software when using one of the following target devices that belong to the 78K0S microcontrollers. This chapter describes the IE-789234-NS-EM1’s system configuration and basic specifications. • Target devices µ • 78K0S/KU1+: PD78F9200, 78F9201, 78F9202 µ ...

Page 11

... System Configuration Figure 1-1 illustrates the IE-789234-NS-EM1’s system configuration. Note 1 Device fine (separately available) Debugger ID78K0S-NS (sold separately) Interface board IE-70000-PC-IF-C (sold separately) IE-78K0S-NS or IE-78K0S-NS-A (sold separately) Interface cable (NS IF cable) AC adapter IE-70000 -MC-PS-B (sold separately) Emulation probe (sold separately) ...

Page 12

... The device file can be downloaded from the website of NEC Electronics Corporation. (http://www.necel.com/micro/ods/eng/index.html) 2. The MC CARD cable is not used in the IE-789234-NS-EM1. 3. Table 1-1 shows the correspondence between the probe interface conversion board, target cable, emulation probe, conversion socket/conversion adapter, and pin header. ...

Page 13

... Hardware Configuration Figure 1-2 shows the IE-789234-NS-EM1’s position in the basic hardware configuration. Figure 1-2. Basic Hardware Configuration Dedicated bus interface Interface board Host machine (sold separately) Interface card (sold separately) 1.3 Basic Specifications The basic specifications of the IE-789234-NS-EM1 are listed in Table 1-2. ...

Page 14

... This chapter introduces the parts of the IE-789234-NS-EM1 main unit. The packing box contains the following. • Emulation board (IE-789234-NS-EM1): • Probe interface conversion board (SIMPLE PROBE Board): 1 • Probe interface conversion board (789222 PROBE Board): 1 • Probe interface conversion board (789234 PROBE Board): 1 • ...

Page 15

... Names of Parts on Board (1) Emulation board (IE-789234-NS-EM1) Figure 2-1. Part Names of IE-789234-NS-EM1 Oscillator for Oscillator for high-speed internal low-speed internal oscillation clock oscillation clock IE-789234-NS-EM1 OSC2 OSC3 LED1 USER VDD LED for monitoring target power supply (2) Probe interface conversion board (SIMPLE PROBE Board) Figure 2-2 ...

Page 16

... Figure 2-3. Part Names of 789222 PROBE Board Top View 789222 PROBE Board Bottom View (4) Probe interface conversion board (789234 PROBE Board) Figure 2-4. Part Names of 789234 PROBE Board Top View 789234 PROBE Board Bottom View 14 CHAPTER 2 PART NAMES CN2 CN1 CN2 CN1 ...

Page 17

... Red: 250 mm cable for power supply line (for V Black: 250 mm cable for GND line (for V Yellow: 250 mm cable for general signals - 26 cables Yellow: For general signals 2.2 Initial Settings of Switches and Jumper Table 2-1. Initial Settings of IE-789234-NS-EM1 Switch Switch SW3-8 SW3-7 Initial setting ...

Page 18

... This chapter describes methods for connecting the IE-789234-NS-EM1 to the IE-78K0S-NS or IE-78K0S-NS-A, emulation probe, etc. Mode setting methods are also described. Caution Connecting or removing components to or from the target system, or making switch or other setting changes must be carried out after the power supply to both the IE system and the target system has been switched OFF ...

Page 19

... Connection 3.1.1 Connection with IE-78K0S-NS or IE-78K0S-NS-A main unit See the IE-78K0S-NS User’s Manual (U13549E) for a description of how to connect the IE-789234-NS-EM1 to the IE-78K0S-NS. See the IE-78K0S-NS-A User’s Manual (U15207E) for a description of how to connect the IE-789234-NS-EM1 to the IE-78K0S-NS-A. 3.1.2 Setup of probe interface conversion board Tighten the four spacers to the SIMPLE PROBE Board using the screws included with the IE-789234-NS-EM1 ...

Page 20

... DD REF signal cables (yellow). <1> Connect CN5 of the IE-789234-NS-EM1 to CN1 of the SIMPLE PROBE Board. <2> Connect CN2 of the SIMPLE PROBE Board to a target cable whose pin count matches that of the target device. Figure 3-2. Connection of SIMPLE PROBE Board and Target Cable ...

Page 21

Table 3-2. Pin Assignment Table for SIMPLE PROBE Board and Target Device CN2 78K0S/KU1+ (10 Pins) − 1 − P20/ANI0/TI000/TOH1 (1) P20/ANI0/TI000/TOH1 (1) − Note P21/ANI1/TI010/TO/INTP0 (10) P21/ANI1/TI010/TO/INTP0 (16) − Note P22/ ...

Page 22

... Connect the QB-80-EP-01T to the probe connectors TGCN1 and TGCN2 of the probe interface conversion board (SIMPLE PROBE Board). <1> Connect CN5 of the IE-789234-NS-EM1 to CN1 of the SIMPLE PROBE Board. <2> Connect TGCN1 and TGCN2 of the SIMPLE PROBE Board to the emulation probe. Figure 3-3. Connection of QB-80-EP-01T and SIMPLE PROBE Board ...

Page 23

... PROBE Board • 78K0S/KB1+: 789234 PROBE Board <1> Connect CN5 of the IE-789234-NS-EM1 to CN1 of the probe interface conversion board. <2> Connect CN2 of the probe interface conversion board to the emulation probe. Figure 3-4. Connection of NP-30MC and Probe Interface Conversion Board ...

Page 24

... Switch and Jumper Settings on Main Unit (1) Settings on the IE-78K0S-NS When using the IE-789234-NS-EM1, set the switches and jumpers on the IE-78K0S-NS as shown in Table 3-3. For details on these switch and jumper settings, refer to the IE-78K0S-NS User’s Manual (U13549E). Caution Incorrect jumper settings may damage the IE-789234-NS-EM1. ...

Page 25

... LED1 (USERVDD), which monitors the connection of the target DD system power supply in the IE-789234-NS-EM1, and as the reference voltage for generating the target interface power supply voltage. The setting of the target interface power supply voltage is shown in Table 3-5. ...

Page 26

... Clock that is mounted by user, (3) Clock input from target system, or (4) High-speed internal oscillation clock. For the external clock, a clock signal is supplied from outside of the target device and the target device’s internal oscillator is not used. An example of the external circuit is shown in part (b) of Figure 3-6. ...

Page 27

... Oscillator already mounted (used) Remark The clock that is supplied by the oscillator of the IE-789234-NS-EM1 (encircled in the figure) is used. (2) Clock that is mounted by user The user can mount any clock supported by the set specifications on the IE-789234-NS-EM1. This feature is effective when debugging at a different frequency from that of the clock already mounted. ...

Page 28

... Remark The pulse that is supplied by the external clock on the target system (encircled in the figure) is used. (4) When using high-speed internal oscillation clock The high-speed internal oscillation clock generated on the IE-789234-NS-EM1 can be used. Figure 3-10. When Using High-Speed Internal Oscillation Clock IE-78K0S-NS or IE-78K0S-NS-A ...

Page 29

... CPU clock source (this selects the user’s clock). 3. Emulation by using the RC oscillator cannot be performed. (1) When using clock that is already mounted on emulation board When the IE-789234-NS-EM1 is shipped, a 10.0 MHz crystal oscillator is already mounted in the IE-789234-NS- EM1’s OSC1 socket. Set SW3 as shown follows in accordance with the option byte setting. ...

Page 30

... Prepare the IE-789234-NS-EM1. <2> Remove the crystal oscillator that is mounted in the IE-789234-NS-EM1’s OSC1 socket. <3> Mount a crystal oscillator in the OSC1 socket from which the crystal oscillator was removed (in <2> above). Insert the pins of the crystal oscillator into the socket aligning the pins as shown in Figure 3-12. ...

Page 31

... Parts board • Ceramic resonator or crystal resonator • Resistor Rx <Steps> <1> Solder the target ceramic resonator or crystal resonator, resistor Rx, capacitor CA, and capacitor CB (all with suitable oscillation frequencies) onto the parts board as shown below. Figure 3-13. Connections on Parts Board Parts board (OSC1 ...

Page 32

... CPU clock source (this selects the user’s clock). (4) When using high-speed internal oscillation clock Set SW3 as shown follows in accordance with the option byte setting. The IE-789234-NS-EM1 uses an 8 MHz oscillator (OSC2) for generating the internal high-speed oscillation clock. ...

Page 33

... The EXTOUT pin on the IE-789234-NS-EM1 outputs a low level for 1.3 Caution Connect a pull-up resistor on the target system because this is an open drain output. (2) EXTIN An event signal can be input from the EXTIN pin on the IE-789234-NS-EM1. Input a high-level pulse signal for 2 CPU operation clocks or more. Figure 3-14. External Trigger Input Position IE-789234-NS-EM1 ...

Page 34

... Switch for Clearing Reset Flag A switch SW4 to clear the reset flag is mounted on the IE-789234-NS-EM1 board. Bit 0 (LVIRF) and bit 4 (WDTRF) of the reset control flag register can be cleared by pressing this switch. At this time, a CPU reset may occur. (1) When program has been stopped Bit 0 (LVIRF) and bit 4 (WDTRF) are cleared ...

Page 35

... Option Byte Settings The option byte provided in the IE-789234-NS-EM1 has the following functions. • Setting of low-speed internal oscillator clock oscillation • Selection of system clock source • RESET pin control • Setting of oscillation stabilization time for when power is applied or reset is input The option byte can be set using SW3 ...

Page 36

... Set SW3-4 to the 0 side, i.e. to “Use RESET pin as dedicated input port (P34)”. <2> Execute the program by enabling the reset mask in the Configuration dialog box of the integrated debugger. • Setting of oscillation stabilization time for when power is applied or reset is input Table 3-10. Setting of Oscillation Stabilization Time SW3-7 Setting SW3-6 Setting ...

Page 37

... Signals directly input to or output from the emulation CPU (2) Signals input from the target system via a gate (3) Other signals The circuits of the IE-789234-NS-EM1 are used as follows for signals listed in (1) to (3) above. The same applies to connection of alternate-function pins, for which no circuit is provided in the IE system. User’s Manual U17381EJ6V0UM ...

Page 38

... Figure 4-2. Emulation Circuit Equivalent Circuit 2 Probe side (Target system) 100 Ω P30 to P33 P40 to P47 P120 to P123 36 1 MΩ kΩ HC4066 (analog switch) D7885 (level shifter) 1 MΩ User’s Manual U17381EJ6V0UM IE system side Emulation CPU µ ( PD789009) IE system side Emulation CPU (FPGA) ...

Page 39

... Figure 4-3. Emulation Circuit Equivalent Circuit 3 Probe side (Target system) P20 to P23 µ (comparator) 100 Ω P34 P121, P122 P130 1 MΩ User’s Manual U17381EJ6V0UM IE system side AV REF Emulation CPU (FPGA) 39 kΩ HC4066 (analog switch) D7885 (level shifter) PC4556 AD7813 (A/D converter) ...

Page 40

... AV REF • Figure 4-4. Emulation Circuit Equivalent Circuit 4 Probe side (Target system MΩ REF − + µ PC741 100 Ω − + µ µ PC393 0.1 F − G6H relay + User’s Manual U17381EJ6V0UM IE system side Power supply generation Power supply detection AV REF ...

Page 41

... CHAPTER 5 This chapter describes the restrictions when using the IE-789234-NS-EM1. (1) Since the IE-789234-NS-EM1 sets the option byte using SW3, the value set to address 80H is not reflected. (2) Some bits of the port register are fixed the target device, but some of them can be overwritten by program ...

Page 42

... Caution on connecting emulation probe When using IE-789234-NS-EM1 control code B or later, do not connect the emulation probe directly to probe connector CN5. Refer to the user's manual included with a control code B or later product or the latest user's manual for the probe interface conversion board corresponding to the target device and connect the emulation probe via this board ...

Page 43

... Remarks 1. The numbers in the Emulation Probe Device Side column refer to the pin number of the target system. 2. The numbers in the SIMPLE PROBE Board CN2 column refer to the probe interface conversion board (IE-789234-NS-EM1) pin. EMULATION PROBE PIN ASSIGNMENT TABLE SIMPLE PROBE Board User’s Manual U17381EJ6V0UM ...

Page 44

... The numbers in the “Emulation Probe” column indicate the corresponding pin number on the emulation probe tip. 3. The numbers in the 789222 PROBE Board CN2 column refer to the probe interface conversion board (IE-789234-NS-EM1) pin to be connected to the emulation probe. 42 EMULATION PROBE PIN ASSIGNMENT TABLE ...

Page 45

... The numbers in the “Emulation Probe” column indicate the corresponding pin number on the emulation probe tip. 3. The numbers in the 789234 PROBE Board CN2 column refer to the probe interface conversion board (IE-789234-NS-EM1) pin to be connected to the emulation probe. EMULATION PROBE PIN ASSIGNMENT TABLE 789234 PROBE Board ...

Page 46

... The following shows the conditions when connecting the emulation probe to the conversion adapter. Follow the configuration below and consider the shape of parts to be mounted on the target system when designing a system. Figure B-1. Distance Between In-Circuit Emulator and Conversion Adapter (When Using NP-30MC) In-circuit emulator IE-78K0S-NS or IE-78K0S-NS-A Emulation board Probe interface conversion board CN2 ...

Page 47

APPENDIX B Figure B-2. Connection Conditions of Target System (When Using NP-30MC) Emulation board Target system Remark NP-30MC is a product of Naito Densei Machida Mfg. Co., Ltd. YSPACK30BK, NSPACK30BK, and YSGUIDE are products of TOKYO ...

Page 48

... APPENDIX B Figure B-3. Distance Between In-Circuit Emulator and Conversion Adapter (When Using QB-80-EP-01T) In-circuit emulator IE-78K0S-NS or IE-78K0S-NS-A Emulation board Figure B-4. Connection Conditions of Target System (When Using QB-80-EP-01T) Emulation probe QB-80-EP-01T Target system 46 NOTES ON TARGET SYSTEM DESIGN SIMPLE PROBE Board 234 mm ...

Page 49

C.1 Major Revisions in This Edition Page CHAPTER 1 GENERAL p.10 Change of Figure 1-1. System Configuration CHAPTER 3 INSTALLATION p.17 Change of Table 3-1. Combination of Probe Interface Conversion Board, Target Cable, and Emulation Probe C.2 Revision History of ...

Page 50

... Prince Edward Road West, Mongkok, Kowloon, Hong Kong MK14 6NP, U.K. Tel: 2886-9318 Tel: 01908-691-133 http://www.hk.necel.com/ Succursale Française NEC Electronics Taiwan Ltd. 9, rue Paul Dautier, B.P. 52 7F, No. 363 Fu Shing North Road 78142 Velizy-Villacoublay Cédex Taipei, Taiwan France Tel: 02-8175-9600 Tel: 01-3067-5800 http://www.tw.necel.com/ Sucursal en Españ ...