M3062PT3-CPE-2 Renesas Electronics America, M3062PT3-CPE-2 Datasheet - Page 91

no-image

M3062PT3-CPE-2

Manufacturer Part Number
M3062PT3-CPE-2
Description
EMULATOR COMPACT M16C/26A,28,29
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheet

Specifications of M3062PT3-CPE-2

Contents
Compact Emulator, IDE, Assembler and Linker
For Use With/related Products
M16C/26A, M16C/28, M16C/29
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
M3062PT3-CPE User’s Manual
REJ10J1007-0400 Rev.4.00 July 29, 2009
Note on Accessing Addresses 00000h and 00001h:
Note on Operating Frequency:
Note on Timeout Setting:
Notes on Pullup Control:
Note on Setting "1" to Protect Bit 2 (PRC2) with Sub Clock:
Note on Setting "1" to Protect Bit 2 (PRC2) in Division by 2 Mode:
Because this product emulates some I/O ports (P0 to P5, P10), you can not pullup ports P0 to P5 by the pullup
control registers, Install the included resistor arrays (51kΩ) as necessary.
The initial value of pullup control register 1 PUR1 of this product is different from that of an actual MCU.
When a VCC level is input to pin CNVss, the value of an actual MCU is “02h” (bit 1 PU11 is “1”), while that of
this product is “00h”.
When the CPU clock is set to the sub-clock (low-speed mode or low power dissipation mode), even if you
enable the PRC2 bit, writing to the register protected by the PRC2 bit (PD9, S3C and S4C) cannot be done
properly. When you enable the PRC2 bit and write to the register protected by the PRC2 (PD9, S3C and S4C),
do not set the CPU clock to the sub-clock.
With the M16C/60 Series MCUs, when a maskable interrupt is generated, the interrupt data (interrupt number
and interrupt request level) stored in addresses 00000h and 00001h are read out. Also, the interrupt request bit is
cleared when address 00000h or 00001h is read out. Consequently, when the address 00000h or 00001h readout
instruction is executed or when address 00000h or 00001h is read out in the cause of a program runaway, a
malfunction occurs in that the interrupt is not executed despite the interrupt request, because the request bit of
the highest priority interrupt factor enabled is cleared.
You can not use this product with a main clock (X
than 1MHz, contact your local distributor.
If you download, execute or single-step a program at a low operating frequency, a communication timeout error
may occur.
Once this command is executed, it remains effective the next time you start the emulator debugger. Therefore,
you do not need to execute this command again.
If the error still occurs in this setting, contact your local distributor.
Under the following conditions, even if you enable the PRC2 bit, writing to the register protected by the PRC2
bit (PD9, S3C and S4C) cannot be done properly.
Therefore, if the condition (1) or (2) applies, when you enable the PRC2 bit and write to the register protected
by the PRC2 (PD9, S3C and S4C), set the CPU clock neither to the main clock in division by 2 mode nor to the
on-chip oscillator clock in division by 2 mode.
Execute the command shown below in the Script Window after starting the emulator debugger.
(1) Between when stop mode is released and when a hardware reset is executed
(2) Between when low power dissipation mode is enabled and when a hardware reset is executed
[Command]
_settimeout 300, 300
IMPORTANT
IN
-X
OUT
) less than 1MHz. To use it with a main clock less
4. Hardware Specifications
Page 89 of 108

Related parts for M3062PT3-CPE-2