E62140 Renesas Electronics America, E62140 Datasheet - Page 6

no-image

E62140

Manufacturer Part Number
E62140
Description
DEV EMULATOR BASE UNIT H8S/2100
Manufacturer
Renesas Electronics America
Type
Microcontrollerr
Datasheet

Specifications of E62140

Contents
E6000 Emulator Unit and 4 Logic Probes
For Use With/related Products
H8S/214x, 213x, 212x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
1.9
1.10 Note on [Register] Window Operation during Program Execution
1.11 [IO] Window
1.12 Source File
1.13 Watch
1.9.1
• Input Radix
• Address Space Size
1.11.1
1.12.1
1.12.2
1.12.3
1.13.1
1.13.2
1.13.3
Assembling and Disassembling
In absolute addressing mode, specify the size (:16, etc.)
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H’ or 0x as the
radix for a hexadecimal input.
During program execution, when the [Register] window is double-clicked, a dialog box to change the
register contents is displayed. However, the operation to change the register contents is invalid during
program execution.
The invalid module display and bit information display in the [IO] window are not supported.
When the source file is moved after the load module has been created, the [Open] dialog box, which
specifies the source file, may be displayed during debugging of the created load module. Select the
corresponding source file.
The columns Event and EXT.2 Trigger in the source window may be switched. You can identify these
columns by displaying a popup menu on either of them.
When different actions have been set on an address from the windows [Event] and [Trace], note the
followings:
Deletion and change for settings must be made in the [Event] window or [Trace] window.
Depending on the generated object code, local variables in a C source file that is compiled with the
optimization option enabled will not be displayed correctly. Check the generated object code by
displaying the [Disassembly] window.
When a name other than a variable name, such as a symbol name or a function name, is specified, no
data is displayed.
Do not enable the automatic update of float- and double-type variables. The values of float- and
double-type variables will not be correctly displayed if they are automatically updated during execution
of the user program. If you want to check the values, use the monitoring function ([Monitor] window).
Deletion and change for settings may not be available on the [Event] column.
If eight or more points have been set as the start points in execution time measurement (Timer On),
changing the settings on the [Event] column may prevent further changes.
Line Assembly
Contents of the [IO] Window
Note on Moving Source File Position after Creating Load Module
Columns in the Source Window
Event Column
Local Variables at Optimization
Variable Name Specification
Display of float- and double-type Variables
4 / 6

Related parts for E62140